Yayın tarihi için Fakülteler listeleme
Toplam kayıt 6401, listelenen: 1-20
-
Analytical solution for continuous-time Kalman tracking filters with colored measurement noise in frequency domain
(Ieee-Inst Electrical Electronics Engineers Inc, 1994)New expressions are given for analytical solutions to the steady-state Kalman gains of the two-state exponentially correlated velocity (ECV) and the three-state exponentially correlated acceleration (ECA) tracking filters ... -
Covalent immobilization of α-amylase onto pHEMA microspheres: preparation and application to fixed bed reactor
(Elsevier Sci Ltd, 1995)Microspheres of poly(2-hydroxyethyl methacrylate) with and without cross-linker were prepared by suspension polymerization. As the amount of cross-linker increased, the equilibrium water content, enzyme loading, immobilization ... -
Interpreting the nonideal reverse bias C-V characteristics and importance of the dependence of Schottky barrier height on applied voltage
(Elsevier Science Bv, 1995)This work presents an attempt related to the charging behaviour of interface states to the nonideal forward bias current-voltage (I-V) and the reverse bias capacitance-voltage (C-V) characteristics of A1-nSi Schottky barrier ... -
Radiation effect on polyadenylic acid in aqueous solution
(Pergamon-Elsevier Science Ltd, 1995)In this study, dilute solution properties of polyadenylic acid (polyA), G values for single strand break formation G(ssb), Arrhenius parameters (25-45 degrees C), the kinetics of strand break in the absence and presence ... -
Analysis of orthotropic plate structures by the direct-dynamic stiffness method
(Pergamon-Elsevier Science Ltd, 1995)… -
Study of small basin hydrology in Anatolia using environmental isotope analysis
(Taylor & Francis Ltd, 1995)The hydrological behaviour of a representative basin in Central Anatolia, Turkey, was studied by isotopic evaluation of water elements. Samples taken from precipitation, groundwater, subsurface water from the unsaturated ... -
Diffusion and selective transport of alkali cations in a polysulfone ion exchange membrane
(Gauthier-Villars, 1995)he diffusion of alkali metals through a charged polysulfonated ICE-450 ion exchange membrane has been measured as a function of pH and conservation of the external solution at 25 degrees C. The permeability and diffusion ... -
A cost-effective method for ultrasound volumetric imaging
(1996)A synthetic receive aperture technique is explored for cost-effective ultrasound scanners with high frame rates and beam density. The technique provides ultrasound volumetric imaging where beam count is very large with 2-D ... -
Segmentation of ultrasonic images using fuzzy sets
(1996)An image segmentation technique based on fuzzy sets for ultrasonic B-scans is presented. The fuzzy c-means algorithm is adapted to B-scan images. The classes constituting a region are obtained through fuzzy partitioning ... -
In-vitro studies of enteric coated diclofenac sodium-carboxymethylcellulose microspheres
(Taylor & Francis Ltd, 1996)Microspheres containing diclofenac sodium (DS) were prepared using carboxymethylcellulose (CMC) as the main support material (1.0, 2.0, 3.0% (w/v)) and aluminium chloride as the crosslinker. Drug to polymer ratios of 1:1, ... -
Comparison of β-galactosidase immobilization by entrapment in and adsorption on poly(2-hydroxyethylmethacrylate) membranes
(Royal Swedish Acad Sciences, 1996)Schottky barrier height shifts depending on the interfacial layer as well as a change of the interface state charge with the forward bias while considering the presence of bulk (semiconductor) series resistance are discussed ... -
Kinetic study of ligand exchange reaction of anions as ligands on DAE-sporopollenin
(Academic Press Inc Jnl-Comp Subscriptions, 1996)The specific rate coefficients and ligand sorption isotherms of Br and I- as ligands on diaminoethyl-sporopollenin were determined as a function of pH and temperature between 20 and 60 degrees C. The ligand exchange rates ... -
Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis
(John Wiley & Sons Inc, 1996)A comparative stress analysis of a polymeric composite hip joint replacement was performed. A prototype short carbon-fiber reinforced PEEK (CF/PEEK) prosthesis was manufactured by injection molding. Finite element (FE) ... -
Application of the dynamic stiffness technique to the in-plane vibrations of plate structures
(Pergamon-Elsevier Science Ltd, 1996)In this study the dynamic stiffness technique, which yields ''exact'' results for a certain class of plate structure, is extended to include in-plane vibrations. Using the equations of motion and edge tractions the stiffness ... -
Natural frequencies of cross-ply laminated singly curved panels
(Pergamon-Elsevier Science Ltd, 1996)… -
Free vibration solution for clamped orthotropic plates using the Kantorovich method
(Academic Press Ltd, 1996)… -
Motion estimation using common spatial frequencies in synthetic aperture imaging
(I E E E, 1996)Correlation processing using fully common spatial frequencies of overlapping subapertures is explored for motion estimation between consecutive excitations in multi-element synthetic aperure imaging. Signals derived from ...