dc.contributor.author | Cift H. | |
dc.contributor.author | Cetik O. | |
dc.contributor.author | Kalaycioglu B. | |
dc.contributor.author | Dirikoglu M.H. | |
dc.contributor.author | Ozkan K. | |
dc.contributor.author | Eksioglu F. | |
dc.date.accessioned | 2020-06-25T15:14:33Z | |
dc.date.available | 2020-06-25T15:14:33Z | |
dc.date.issued | 2010 | |
dc.identifier.issn | 18770517 | |
dc.identifier.uri | https://doi.org/10.1016/j.rcot.2010.03.019 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/2138 | |
dc.description.abstract | Introduction: The objective of this biomechanical study was to compare the respective efficiency of plate-screw fixation and screw fixation in an experimental model of a Schatzker type IV fracture. Hypothesis: Screw fixation and plate fixation have a similar load to failure. Materials and methods: This study compares the stability of Schatzker type IV medial tibial plateau fractures fixed with either three 6.5. mm cancellous bone screws with a 16. mm threaded segment or with six-holed buttress T plate-screw system. A Schatzker type IV fracture was modeled on an artificial bone model. In a first group of 10 fracture models, following the anatomical reduction, fractures were stabilized with screws with washers. In the second group of 10 fracture models, fractures were stabilized with T plate. After fixation, ascending axial compression was applied on bone models (Instron machine). Results: Load bearing capacity was 1397.6 ± 194.4 in group I and 2153.2 ± 204.4 in group II. The difference between two groups were statistically significant (p<0.001). Discussion: According to this result, experimental load bearing of bone models indicates that plate-screw fixation system has a significantly higher stabilization capacity than fixation with three screws alone. Our hypothesis was not confirmed. In order to maintain anatomical repositioning, the plate-screw system is a more stable fixation method than the screw in medial tibial plateau fractures of Schatzker type IV. © 2010 Elsevier Masson SAS. | en_US |
dc.language.iso | fra | en_US |
dc.relation.isversionof | 10.1016/j.rcot.2010.03.019 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Biomechanical test | en_US |
dc.subject | Bone model | en_US |
dc.subject | Fixation | en_US |
dc.subject | Medial tibial plateau fractures | en_US |
dc.title | Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker IV). A model study | en_US |
dc.title.alternative | Étude comparative biomécanique de l'ostéosynthèse par plaque vissée versus vis dans les fractures du plateau tibial médial de type Schatzker 4 | en_US |
dc.type | article | en_US |
dc.contributor.department | Kırıkkale Üniversitesi | en_US |
dc.identifier.volume | 96 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.startpage | 313 | en_US |
dc.identifier.endpage | 314 | en_US |
dc.relation.journal | Revue de Chirurgie Orthopedique et Traumatologique | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |