Basit öğe kaydını göster

dc.contributor.authorCift H.
dc.contributor.authorCetik O.
dc.contributor.authorKalaycioglu B.
dc.contributor.authorDirikoglu M.H.
dc.contributor.authorOzkan K.
dc.contributor.authorEksioglu F.
dc.date.accessioned2020-06-25T15:14:33Z
dc.date.available2020-06-25T15:14:33Z
dc.date.issued2010
dc.identifier.issn18770517
dc.identifier.urihttps://doi.org/10.1016/j.rcot.2010.03.019
dc.identifier.urihttps://hdl.handle.net/20.500.12587/2138
dc.description.abstractIntroduction: The objective of this biomechanical study was to compare the respective efficiency of plate-screw fixation and screw fixation in an experimental model of a Schatzker type IV fracture. Hypothesis: Screw fixation and plate fixation have a similar load to failure. Materials and methods: This study compares the stability of Schatzker type IV medial tibial plateau fractures fixed with either three 6.5. mm cancellous bone screws with a 16. mm threaded segment or with six-holed buttress T plate-screw system. A Schatzker type IV fracture was modeled on an artificial bone model. In a first group of 10 fracture models, following the anatomical reduction, fractures were stabilized with screws with washers. In the second group of 10 fracture models, fractures were stabilized with T plate. After fixation, ascending axial compression was applied on bone models (Instron machine). Results: Load bearing capacity was 1397.6 ± 194.4 in group I and 2153.2 ± 204.4 in group II. The difference between two groups were statistically significant (p<0.001). Discussion: According to this result, experimental load bearing of bone models indicates that plate-screw fixation system has a significantly higher stabilization capacity than fixation with three screws alone. Our hypothesis was not confirmed. In order to maintain anatomical repositioning, the plate-screw system is a more stable fixation method than the screw in medial tibial plateau fractures of Schatzker type IV. © 2010 Elsevier Masson SAS.en_US
dc.language.isofraen_US
dc.relation.isversionof10.1016/j.rcot.2010.03.019en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBiomechanical testen_US
dc.subjectBone modelen_US
dc.subjectFixationen_US
dc.subjectMedial tibial plateau fracturesen_US
dc.titleBiomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker IV). A model studyen_US
dc.title.alternativeÉtude comparative biomécanique de l'ostéosynthèse par plaque vissée versus vis dans les fractures du plateau tibial médial de type Schatzker 4en_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume96en_US
dc.identifier.issue3en_US
dc.identifier.startpage313en_US
dc.identifier.endpage314en_US
dc.relation.journalRevue de Chirurgie Orthopedique et Traumatologiqueen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster