Basit öğe kaydını göster

dc.contributor.authorErdemir, A.
dc.contributor.authorEldeniz, A. U.
dc.contributor.authorAri, H.
dc.contributor.authorBelli, S.
dc.contributor.authorEsener, T.
dc.date.accessioned2020-06-25T17:43:49Z
dc.date.available2020-06-25T17:43:49Z
dc.date.issued2007
dc.identifier.citationBu makale açık erişimli değildir.en_US
dc.identifier.issn0143-2885
dc.identifier.urihttps://doi.org10.1111/j.1365-2591.2007.01234.x
dc.identifier.urihttps://hdl.handle.net/20.500.12587/3909
dc.descriptionErdemir, Ali/0000-0003-1140-3887en_US
dc.descriptionWOS: 000245988400008en_US
dc.descriptionPubMed: 17309740en_US
dc.description.abstractAim To determine the influence of various irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpiece. Methodology One hundred and forty teeth with single canals and mature apices, scheduled for extraction for either periodontal or prosthetic reasons in 76 patients were used. Following informed written consent local anaesthesia was administered, access cavities were prepared and pulp tissue removed. The teeth were then randomly divided into seven groups according to the irrigating solutions used. The root canal length measurements were completed using the Tri Auto ZX handpiece with automatic reverse function in the presence of one or other of the following solutions: 0.9% saline, 2.5% NaOCl, 3% H2O2, 0.2% chlorhexidine, 17% EDTA, Ultracaine((R)) D-S or in the absence of an irrigating solution (control). Files were immobilized in the access cavity with composite resin. After extraction, the apical regions of the teeth were exposed and the file tips examined under a stereomicroscope. Distances between the file tips and the apical constriction were measured (mm) and analysed using a one-way ANOVA and post hoc Tukey test. Results Mean distances from the apical constriction to the file tip were longer in the 0.9% saline group (P < 0.05). There was no statistically significant difference on file tip position between the other solutions. Conclusions Tri Auto ZX gave reliable results with all irrigating solutions apart from in the presence of 0.9% saline.en_US
dc.language.isoengen_US
dc.publisherBlackwell Publishingen_US
dc.relation.isversionof10.1111/j.1365-2591.2007.01234.xen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjecthandpieceen_US
dc.subjectirrigation solutionsen_US
dc.subjectprofileen_US
dc.subjectroot canal lengthen_US
dc.subjectTri Auto ZXen_US
dc.titleThe influence of irrigating solutions on the accuracy of the electronic apex locator facility in the Tri Auto ZX handpieceen_US
dc.typearticleen_US
dc.identifier.volume40en_US
dc.identifier.issue5en_US
dc.identifier.startpage391en_US
dc.identifier.endpage397en_US
dc.relation.journalInternational Endodontic Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster