Basit öğe kaydını göster

dc.contributor.authorCirpar, O.
dc.contributor.authorArikan, O. K.
dc.contributor.authorKendi, T.
dc.contributor.authorGorgulu, O.
dc.date.accessioned2020-06-25T18:06:42Z
dc.date.available2020-06-25T18:06:42Z
dc.date.issued2012
dc.identifier.citationclosedAccessen_US
dc.identifier.issn1781-782X
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5326
dc.descriptiongorgulu, orhan/0000-0001-6566-843Xen_US
dc.descriptionWOS: 000314259700002en_US
dc.descriptionPubMed: 23409550en_US
dc.description.abstractIs there any correlation between chronic noise-induced hearing loss and mastoid pneumatization volume? A preliminary study. Objectives: To investigate the possible association between chronic noise-induced hearing loss and the volume of mastoid pneumatization. Methodology: The study involved 46 subjects employed in the press and montage department of a gun factory: 28 in the study group with noise-induced hearing loss and 18 in the control group with no hearing loss. The volume of mastoid pneumatization was measured with computed tomography. Student's test was used in the comparison of the mastoid volumes of the study and the control groups. Results: The intergroup evaluations showed no significant difference between the study and control group with regards to age, use of substances or ototoxic drugs, systemic diseases, use of personal hearing protectors, duration of occupational and non-occupational noise exposure was observed (P > 0.05). The mean values of mastoid pneumatization in the study and the control groups were 9717.6 mm(3) and 11005.8 mm(3), respectively. Although the volume of mastoid pneumatization was smaller in the study group than in the control group, this difference was not statistically significant (P > 0.05). Conclusions: This preliminary study showed that there was no significant correlation between mastoid pneumatization volume and chronic noise-induced hearing loss. However, this correlation could be significant in further studies with a larger number of subjects.en_US
dc.language.isoengen_US
dc.publisherRoyal Belgian Soc Ear, Nose, Throat, Head & Neck Surgeryen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectNoise-induced hearing lossen_US
dc.subjectoccupational hearing lossen_US
dc.subjecthearing lossen_US
dc.subjectmastoid aerationen_US
dc.subjectcomputed tomographyen_US
dc.titleIs there any correlation between chronic noise-induced hearing loss and mastoid pneumatization volume? A preliminary studyen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume8en_US
dc.identifier.issue4en_US
dc.identifier.startpage241en_US
dc.identifier.endpage245en_US
dc.relation.journalB-Enten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster