Basit öğe kaydını göster

dc.contributor.authorAslan, Mustafa
dc.contributor.authorKucukaslan, Ibrahim
dc.contributor.authorMulazimoglu, Serkan
dc.contributor.authorSoyer, Tutku
dc.contributor.authorSenyucel, Mine
dc.contributor.authorCakmak, Murat
dc.contributor.authorAslan, Selim
dc.date.accessioned2020-06-25T18:07:23Z
dc.date.available2020-06-25T18:07:23Z
dc.date.issued2013
dc.identifier.issn0939-7248
dc.identifier.issn1439-359X
dc.identifier.urihttps://doi.org/10.1055/s-0032-1324800
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5562
dc.descriptionKucukaslan, Ibrahim/0000-0002-3458-4409; Scholbach, Jakob/0000-0001-6324-6268; Soyer, Tutku/0000-0003-1505-6042en_US
dc.descriptionWOS: 000317719000008en_US
dc.descriptionPubMed: 23093435en_US
dc.description.abstractAim Ultrasonography (US) has high diagnostic value in testicular torsion but is vulnerable to several potential errors, especially in the early period. Echotexture (ETX) analysis software provides a numerical expression of B-mode images and allows quantitative evaluation of blood flow due to ischemic damage using power Doppler US (PDUS) analysis. Our aim in this study was to determine the diagnostic value and effective parameters of EXT analysis software in the early period of torsion using B-mode and PDUS images. Materials and Methods In this study, eight rats were used. Following anesthesia, the right testis was rotated to a 1080-degree counterclockwise position whereas the left testis was left in place to have a control group. B-mode and PDUS images of both sides were recorded with a portable US device immediately (0 hour) and 1 and 2 hours after torsion. The B-mode images were analyzed in terms of gradient, homogeneity, and contrast using the BS200pro software (BAB Digital Imaging System 2007, Ankara, Turkey). Intensity (I)-red and area (A)-red values were measured on PDUS images with the Pixelflux (Version 1.0, Chameleon-Software, Leipzig, Germany). The data were evaluated by the Mann-Whitney U and Wilcoxon tests. Results Data from B-mode US image EXT analysis showed no significant difference between the right and left testicles in 0 to 2 hours (p > 0.05). The values obtained from PDUS analysis (I-red and A-red) significantly decreased at the testicular torsion side at the end of the second hour (p < 0.05). I-red and A-red values at 0 to 1 hour of torsion indicated similar blood flow alterations (p > 0.05) whereas the flow was significantly lower at 2 hours (p < 0.05). Conclusion In experimental testicular torsion, ischemic changes can be detected by PDUS power/angiomode using blood flow alterations as early as the second hour. Tissue damage cannot be evaluated within the first 2 hours of torsion with B-mode ETX analysis.en_US
dc.language.isoengen_US
dc.publisherGeorg Thieme Verlag Kgen_US
dc.relation.isversionof10.1055/s-0032-1324800en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjecttesticular torsionen_US
dc.subjectultrasonographyen_US
dc.subjectechotextureen_US
dc.subjectexperimenten_US
dc.subjectbiomedical image processingen_US
dc.titleQuantitative Software Analysis of Ultrasonographic Textures in Experimental Testicular Torsionen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume23en_US
dc.identifier.issue2en_US
dc.identifier.startpage134en_US
dc.identifier.endpage139en_US
dc.relation.journalEuropean Journal Of Pediatric Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster