Basit öğe kaydını göster

dc.contributor.authorAtmaca, Nurgul
dc.contributor.authorSimsek, Ozkan
dc.contributor.authorEmre, Bahri
dc.date.accessioned2020-06-25T18:12:28Z
dc.date.available2020-06-25T18:12:28Z
dc.date.issued2014
dc.identifier.citationAtmaca N., Şimşek Ö., Emre M. B. (2014). Some electrocardiographic values of Angora goats. Ankara Üniversitesi Veteriner Fakültesi Dergisi, 61(1), 15 - 19.en_US
dc.identifier.issn1300-0861
dc.identifier.issn1308-2817
dc.identifier.urihttps://doi.org/10.1501/Vetfak_0000002599
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5930
dc.descriptionWOS: 000334986600003en_US
dc.description.abstractElectrocardiography is a noninvasive and easily applied technique used in the determination of cardiac hypertrophy and dilatation, the classification of cardiac arrhythmias, and the diagnosis of conduction abnormalities. The aim of this study was to determine the normal electrocardiographic (ECG) values in Angora goats. A total of 30 healthy Angora goats of both sexes, ranging in age from 1 to 2 years, were used in the study. The 3 standard bipolar limb leads (I, II, III) and unipolar augmented limb leads (aVR, aVL, aVF) were recorded with the goats standing. The morphology and amplitude of P waves, QRS complexes, and T waves were analyzed in all leads. Cardiac rhythm, heart rate, and the durations of P, QRS and T waves, as well as the PR interval and QT interval, were calculated in the limb leads. The mean electrical axis for each individual was determined from the net amplitude of the QRS complex in leads I and III. Most of the animals had sinus rhythm. The mean heart rate was 108.71 +/- 3.289 per minute and ranged from 75 to 143. The mean electrical axis was between -178 degrees and +170 degrees. In conclusion, the findings presented here may be useful to clinicians and researchers as reference values for the normal ECG of Angora goats.en_US
dc.language.isoengen_US
dc.publisherAnkara Univ Pressen_US
dc.relation.isversionof10.1501/Vetfak_0000002599en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAngora goaten_US
dc.subjectconfigurationen_US
dc.subjectelectrocardiogramen_US
dc.subjectwaveen_US
dc.titleSome electrocardiographic values of Angora goatsen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume61en_US
dc.identifier.issue1en_US
dc.identifier.startpage15en_US
dc.identifier.endpage19en_US
dc.relation.journalAnkara Universitesi Veteriner Fakultesi Dergisien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster