Basit öğe kaydını göster

dc.contributor.authorKaymak, Çetin
dc.contributor.authorKoçak, Orhan Murat
dc.contributor.authorBabadağ, Yıldız
dc.contributor.authorKoçak, Emine
dc.contributor.authorApan, Alpaslan
dc.date.accessioned2020-06-25T14:40:51Z
dc.date.available2020-06-25T14:40:51Z
dc.date.issued2011
dc.identifier.issn1300-0578
dc.identifier.urihttps://app.trdizin.gov.tr/publication/paper/detail/TVRFNE9UVXlNZz09
dc.identifier.urihttps://hdl.handle.net/20.500.12587/607
dc.description.abstractAmaç: Kognitif fonksiyon, bilinç düzeyi, hafıza, oryantasyon, konsantrasyon, genel bilgi, zeka, anlama ve yargı yeteneği bileşenlerinden oluşur. Postoperatif kognitif disfonksiyon (POKD), bellek ve konsantrasyondaki yetersizlikle karakterize multifaktoriyel bir tablodur. Hastanın derlenme evresi içinde bilişsel işlevlerinin eski düzeyine gelmesi anestetik maddenin farmakokinetiği, anestezi ve cerrahi yöntem ile ilişkili olmaktadır. Bu çalışmada, düşük ve yüksek akımlı desfluran anestezisi uygulamasında preoperatif ve postoperatif dönemdeki bilişsel işlevlerin incelenmesi amaçlandı. Yöntem: Çalışmaya Lokal Etik Kurul onayı alındıktan sonra ASA I-II, 15-55 yaş arası dahil edilen 32 erişkin olgu, yüksek akım. (Grup I, n16) ve düşük akım (Grup II, n-16) olmak üzere iki gruba ayrıldı. Premedikasyon yapılmadı. Anestezi indüksiyonu tiyopental 5-7 mg kg'1 ve fentanil 1,5 ]ug kg'1 i.v ile yapıldı ve endotrakeal entübasyon öncesi nöromusküler gevşeme için rokuronyum 0,6 mg kg'1 kullanıldı. Yüksek ve düşük akımlı anestezi grubundaki hastalarda sırasıyla %50 N2002 4 l dk'1 ve 1 l dk1 akım ile desfluran uygulaması yapıldı. Hastaların derlenmesi 5., 10., 15., 30. ve 60. dakikalarda Modifiye Aldrete Skoru (MAS) ile değerlendirildi. Hastaların kognitif fonksiyonları preoperatif ve postoperatif 1. saatte sırasıyla Sözel İşitsel Bellek Testi (SIBT) ve S troop İnterferans Test (SİT) ile değerlendirildi. Bulgular: Her iki grupta preoperatif ve postoperatif SİBT1, SİBT 5, SİBT 6, SİBT 7, SİBT 8 ve SÎT skorlarında anlamlı bir etkileşim saptanmamıştır. Postoperatif uyanma zamanı ile SİBT 1, SİBT 5, SİBT 6, SİBT 7, SİBT 8, SIT skorları arasında anlamlı bir korelasyon saptanmamıştır. Sonuç: Her iki anestezi uygulaması bilişsel işlevler açısından farklılık göstermemiştir. Postoperatif derlenme zamanı ve bilişsel işlevler arasında ilişki bulunmaması nedeniyle desfluran anestezisindeki taze gaz miktarının kognitif bilişsel fonksiyonları etkilemediğini düşünmekteyiz.en_US
dc.description.abstractObjective: Cognitive function consists of the level of consciousness, memory, orientation, concentration, general knowledge, intelligence, understanding and judgment. Postoperative cognitive dysfunction is a multifactor state which is characterized by disability of memory and concentration. At the recovery stage, the patient's cognitive functions returning to its original level is closely related with pharmacokinetics of the anesthetic material, anesthesia, desfluran used in low and high flow anesthesia. This study aimed at examining cognitive functions in the preoperative ve postoperative period when low and high flow of desfluran anesthesia was applied. Methods: After Institutional Ethics Committee approval, ASA IIII, 32 patients of 15-55 ages two groups. One group (Group I, n16) had high flow and the other (Group II, n16) had low flow. Premedication was not applied. Anesthesia was induced with 1.5 jig kg' fentanyl and 5-7 mg kg' thiopental. Endotracheal intubation was performed after 0.6 mg kg' rocuronium. Patients, included in Group I and in Group II were applied 4 L min-1 50 % N2002 and 1 L min ' 50 % N2002 respectively. Patient's recovery parameters were evaluated with Modified Aldrete Score (MAS) at 5., 10., 15., 30. and 60. minutes. Cognitive functions of the patients were evaluated with Verbal Auditory Memory Test (VAMT) and Stroop Interference Test (SIT). Results: No significant result was found in the preoperative and postoperative VAMT 1, VAMT 5, VAMT 6, VAMT 7, VAMT 8 and SIT scores between Group I and Group II. No correlation was confirmed between postoperative recovery time and VAMT 1, VAMT 5, VAMT 6, VAMT 7, VAMT 8, SIT score. Conclusion: Neither of the anesthetic techniques showed differences with respect to cognitive functions. We conclude that since no relationship between postoperative recovery time and cognitive functions was found, the amount of fresh gas used in the desfluran did not affect the cognitive functions.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCerrahien_US
dc.titleYüksek ve düşük akımlı desfluran anestezisinde kognitif fonksiyonların değerlendirilmesien_US
dc.title.alternativeThe evalution of cognitive functions in desflurane anesthesia with low and high flowen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume19en_US
dc.identifier.issue2en_US
dc.identifier.startpage124en_US
dc.identifier.endpage129en_US
dc.relation.journalAnestezi Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster