Basit öğe kaydını göster

dc.contributor.authorColak, Hakan
dc.contributor.authorTokay, Ugur
dc.contributor.authorUzgur, Recep
dc.contributor.authorUzgur, Zeynep
dc.contributor.authorErcan, Ertugrul
dc.contributor.authorHamidi, Mehmet M.
dc.date.accessioned2020-06-25T18:16:40Z
dc.date.available2020-06-25T18:16:40Z
dc.date.issued2016
dc.identifier.citationÇolak H, Tokay U, Uzgur R, Uzgur Z, Ercan E, Hamidi MM. The Effect of Different Adhesives and Setting Times on Bond Strength between Biodentine and Composite. Journal of Applied Biomaterials & Functional Materials. 2016;14(2):217-222.en_US
dc.identifier.issn2280-8000
dc.identifier.urihttps://doi.org/10.5301/jabfm.5000266
dc.identifier.urihttps://hdl.handle.net/20.500.12587/6590
dc.descriptionColak, Hakan/0000-0001-8262-0913; Hamidi, Mehmet Mustafa/0000-0003-3461-7925; ERCAN, Ertugrul/0000-0002-4753-6553en_US
dc.descriptionWOS: 000388385600012en_US
dc.descriptionPubMed: 27149941en_US
dc.description.abstractBackground: The aim of this study was to evaluate the effects of 3 different adhesives with different functional monomers, on the shear bond strength (SBS) of Biodentine (R). Methods: Acrylic blocks (n = 90) were prepared and a 2-mm height x 4-mm diameter hole was opened in each block. Every hole was completely restored with Biodentine (R). Before preparation of composite restorations over the Biodentine (R) (2-mm height x 2-mm diameter), 3 different adhesives (Etch-37 (37%) w/BAC by Bisco & Prime Bond N&T, Clearfil S-3 Bond and Adper Prompt L-Pop) were applied. SBS was evaluated using a universal testing machine, and failure mode for each sample was recorded. The results were statistically analyzed using 2-way ANOVA and post hoc Tukey test. Results: When the megapascal values of all groups were compared, although there was no statistically significant difference in the different setting times (p>0.05), statistically significant differences were observed among all adhesive groups (p<0.05). Moreover, the highest SBS values were observed in the Clearfil S-3 Bond group. Conclusions: Clinical performance of Biodentine (R) may be affected by adhesive procedures and its setting time.en_US
dc.language.isoengen_US
dc.publisherWichtig Publishingen_US
dc.relation.isversionof10.5301/jabfm.5000266en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBiodentine (R)en_US
dc.subjectSelf-etch adhesivesen_US
dc.subjectSEMen_US
dc.subjectShear bond strength testen_US
dc.subjectTotal-etchen_US
dc.titleThe effect of different adhesives and setting times on bond strength between Biodentine and compositeen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume14en_US
dc.identifier.issue2en_US
dc.identifier.startpageE217en_US
dc.identifier.endpageE222en_US
dc.relation.journalJournal Of Applied Biomaterials & Functional Materialsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster