Basit öğe kaydını göster

dc.contributor.authorSahin, Volkan
dc.contributor.authorJodati, Hossein
dc.contributor.authorEvis, Zafer
dc.date.accessioned2021-01-14T18:10:32Z
dc.date.available2021-01-14T18:10:32Z
dc.date.issued2020
dc.identifier.citationBu makale açık erişimli değildir.en_US
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2019.09.001
dc.identifier.urihttps://hdl.handle.net/20.500.12587/12658
dc.descriptionEvis, Zafer/0000-0002-7518-8162en_US
dc.descriptionWOS:000545315200013en_US
dc.descriptionPubMed: 31672424en_US
dc.description.abstractStatement of problem. Recent commercial extended-pour irreversible hydrocolloid impression materials (EPIHIMs) claim to maintain dimensional stability up to 120 hours. However, data regarding their mechanical properties and performance after 120 hours of storage are lacking. Purpose. The purpose of this in vitro study was to test the elastic recovery, strain in compression, and tear strength properties of 5 commercially available EPIHIMs, immediately after preparation and after 120 hours of storage under specific storage conditions. Material and methods. A total of 150 specimens were prepared in accordance with the ISO 21563:2013 standard from 5 commercially available EPIHIMs (Blueprint Xcreme, Kromopan, Alginmax, Hydrogum 5, and Alginelle). The specimens were subjected to elastic recovery, strain in compression, and tear strength tests immediately after specimen preparation (n=5) and after 120 hours of storage inside clear plastic zipper bags held at 23 degrees C (n=5). Data were analyzed with a multivariate analysis of variance (MANOVA) test for brand and duration parameters. Normality of data was analyzed with the Shapiro-Wilk test. The Duncan test or Games-Howell test was used for multiple comparisons (alpha=.05). Results. Elastic recovery and strain in compression values of the EPIHIMs tested were affected by brand and duration parameters (P<.001). Tear strength values of the EPIHIMs tested were affected by brand (P<.001); however, they were not affected by duration (P>.05). Data distribution was normal except for Alginmax in terms of the elastic recovery values and Blueprint Xcreme in terms of the strain in compression values (P<.05). Significant interactions were present between brand and duration for the strain in compression and tear strength values of the EPIHIMs tested (P<.05). Statistically significant difference was not found among mean elastic recovery values of the tested EPIHIM brands (P<.001). Moreover, a statistically significant increase was present in elastic recovery values of the tested EPIHIMs after 120 hours of storage (P<.001). Statistically significant difference was not found among mean strain in compression values of the tested EPIHIM brands tested immediately after preparation (P>.05). However, 120 hours of storage led both to a statistically significant decrease in mean strain in compression values of the tested EPIHIMs (P<.001) except for Alginelle (P>.05) and a statistically significant difference among mean strain in compression values of the tested EPIHIM brands (P<.001). Storage time did not influence mean tear strength values of the EPIHIMs tested (P>.05). However, statistically significant differences were present among mean tear strength values of the tested EPIHIM brands tested immediately after preparation (P<.001) and after 120 hours of storage (P<.001). Conclusions. Despite variations in elastic recovery, strain in compression, and tear strength properties of the EPIHIMs tested, all the materials fulfilled the requirements to comply with the ISO 21563:2013 standard even after 120 hours of storage.en_US
dc.description.sponsorshipTurkiye Bilimsel ve Teknolojik Arastirma Kurumu (The Scientific and Technological Research Council of Turkey) [215M056]en_US
dc.description.sponsorshipSupported by Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (The Scientific and Technological Research Council of Turkey) with the project #215M056.en_US
dc.language.isoengen_US
dc.publisherMOSBY-ELSEVIERen_US
dc.relation.isversionof10.1016/j.prosdent.2019.09.001en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEffect of storage time on mechanical properties of extended-pour irreversible hydrocolloid impression materialsen_US
dc.typearticleen_US
dc.contributor.departmentKKÜen_US
dc.identifier.volume124en_US
dc.identifier.issue1en_US
dc.identifier.startpage69en_US
dc.identifier.endpage74en_US
dc.relation.journalJOURNAL OF PROSTHETIC DENTISTRYen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster