Show simple item record

dc.contributor.authorÖzpolat, Berkant
dc.contributor.authorYılmaz, Seyhan
dc.contributor.authorBüyükkoçak, Ünase
dc.contributor.authorGünaydın, Serdar
dc.contributor.authorÇavuşoğlu, Tarık
dc.date.accessioned2021-01-14T18:16:24Z
dc.date.available2021-01-14T18:16:24Z
dc.date.issued2011
dc.identifier.citationÖzpolat B., Yılmaz S., Büyükkoçak Ü., Günaydın S., Çavuşoğlu T. (2011). Fotokatalizörlerin anti-mikrobiyal etkinliğinin klinik ve laboratuar ortamda değerlendirilmesi. Journal of Clinical and Analytical Medicine, 2(2), 32 - 35.en_US
dc.identifier.issn1309-2014
dc.identifier.urihttps://app.trdizin.gov.tr/makale/TVRJNE1qSTBOQT09
dc.identifier.urihttps://hdl.handle.net/20.500.12587/13167
dc.description.abstractAmaç Çalışmamız yeni kuşak fotokatalizörlerden olan apatit kaplı demir titanat uygulamasının, olası anti-mikrobiyal etkinliğinin araştırılmasını; in vitro ve hastane içi uygulamalarda test edilmesini amaçlamaktadır. Gereç ve Yöntemler 30 adet standart steril petri kutusu buhar fazında 20 ppm apatit kaplı demir titanat uygulamasına tabi tutulduktan sonra floresan ışık altında 4 gün tutuldu. 10 kutuya 0,5 McFarland (1.5X108 CFU/mL -CFU=koloni oluşturucu birim) Pseudomonas aeruginosa, 10 kutuya 0,5 McFarland Acinetobacter baumannii ekimi yapıldı. 10 kutu ise kontrol olarak saklandı. Örnekler uygulama sonrası bakteriyel sağkalım oranı (CFUX100/CFU) yönünden değerlendirildi. İkinci aşamada hastanede belli mekânlarda yüzeylere özel uygulama kitiyle buhar fazında 0.012 L/m2 uygulama yapıldı. Fotokatalizör uygulamasından hemen önce ve 1 ay sonra havadaki parçacık miktarı lumimetre ile ölçülerek karşılaştırıldı. Bulgular Bakteriyel sağkalım oranları Pseudomonas aeruginosa için fotokatalizör kaplı yüzeylerde kontrol grubuna oranla 2. günden sonra anlamlı olarak azalmış bulundu (p<0.001) (%60±8 / %95±9). Fark 4. güne kadar artarak devam etti (3. gün: %35±5 / %90±9; 4. gün: %22±5 / %85±8). Acinetobacter baumannii uygulanan yüzeylerde de bakteriyel sağkalım 2. günden sonra anlamlı olarak düşük çıktı (%55±7 / %87±8) (p<0.01). Fark 4. güne kadar artarak devam etti (3. gün: %40±5 / %80±8; 4. gün: %15±5 / %78±7). Fotokatalizör kaplı yüzeylerde havadaki parçacık miktarında, ameliyathanede %97.15, yoğun bakımda %95.61, doktor odasında %98.30, serviste %94.13 ve hastane mutfağında %97.04 azalma belirlendi. Sonuç Fotokatalizör kaplamanın öncü değerlendirme çalışmalarından biri olan araştırmamız sonucunda, gerek laboratuar gerekse klinik ortamlarda bakterisit ve bakteriostatik etkinliği ortaya konulmuş ve hastane sterilizasyonunda ucuz ve güvenli bir alternatif olabileceği düşünülmüştür.en_US
dc.description.abstractAim This study aims at investigating and testing the tentative antimicrobial efficacy; in vitro and in- hospital applications of apatite coated ferrum titanate which is one of the new generation photocatalysts. Material and Methods 30 sterile petri dishes were kept under florescent light for 4 days following the application of 20 ppm apatite coated ferrum titanate aerosol. 0.5 McFarland (1.5X108 CFU/mL -CFU=colony forming unit) Pseudomonas aeruginosa and 0.5 McFarland Acinetobacter baumannii were cultured on 10 separate dishes. 10 unprocessed dishes were used as controls. Samples were evaluated for bacterial survival rate (CFUX100/CFU) after application. In the second step, same photocatalyst aerosol was applied as 0.012 L/m2 with the specific kit on the surfaces of different units within the hospital. Particle count was measured and compared before and one-month after the photocatalyst application by lumimeter. Results Bacterial survival rate was significantly lower on photocatalyst applied surfaces versus control for Pseudomonas aeruginosa after second day of application (p&lt;0.001) (60&plusmn;8% / 95&plusmn;9%). This difference continued up to the 4th day gradually (3. day: 35&plusmn;5% / 90&plusmn;9%; 4. day:22&plusmn;5% / 85&plusmn;8%). Bacterial survival rate was significantly lower on photocatalyst applied surfaces versus control for Acinetobacter baumannii after the second day of application (55&plusmn;7% / 87&plusmn;8%) (p&lt;0.01). This difference continued up to the 4th day gradually (3. day:40&plusmn;5% / 80&plusmn;8%; 4. day:15&plusmn;5% / 78&plusmn;7%). Particle count on photocatalyst applied surfaces diminished 97.15% in operating room, 95.61% in ICU, 98.30 in physicians&amp;#8217; room, 94.13% in wards and 97.04% in hospital kitchen. Conclusions As a result of our pioneering study on the evaluation of photocatalyst, we think that it may be one of the economic and safe alternative methods of hospital sterilization based on bactericidal and bacteriostatic efficacy confirmed in both laboratory and clinical applications.en_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGenel ve Dahili Tıpen_US
dc.titleFotokatalizörlerin anti-mikrobiyal etkinliğinin klinik ve laboratuar ortamda değerlendirilmesien_US
dc.title.alternativeClinical and laboratory evaluation of anti-microbial efficacy of photocatalystsen_US
dc.typearticleen_US
dc.identifier.volume2en_US
dc.identifier.issue2en_US
dc.identifier.startpage32en_US
dc.identifier.endpage35en_US
dc.relation.journalJournal of Clinical and Analytical Medicineen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record