Basit öğe kaydını göster

dc.contributor.advisorAYLİN AKBAY OBA
dc.contributor.authorBEYZA ECEM ALKAÇ
dc.date.accessioned2022-01-11T07:01:44Z
dc.date.available2022-01-11T07:01:44Z
dc.date.issued2021en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12587/18069
dc.description.abstractPrefabrike Zirkonya Kronlarda Kullanılan Farklı Simantasyon Materyallerinin Mikrosızıntısının Değerlendirilmesi Çalışmamızın amacı, çekilmiş süt anterior dişlere üç farklı yapıştırma simanı ile simante edilen prefabrike zirkonya kronlarda gözlenen mikrosızıntı düzeylerini değerlendirmek ve karşılaştırmaktır. Çalışmamızda prefabrike zirkonya kronların (NuSmile, TX, USA) simantasyonu amacıyla iki farklı RMCİS içerikli materyal (Ketac Cem Plus, 3M ESPE, USA ve FujiCEM Evolve, GC, Japan) ve bir self adeziv rezin siman (RelyX U200, 3M ESPE, USA) kullanılmıştır. Çalışmaya dahil edilme kriterlerine sahip 36 adet süt anterior diş (18 santral, 18 lateral), randomize şekilde üç gruba ayrılmıştır. Prefabrike zirkonya kronlar ait oldukları gruptaki materyalin üretici firma talimatlarına göre prepare edilen dişlere simante edilmiştir. Hazırlanan restorasyonlara 5 °C ile 55 °C arasında; 6000 devirde termal siklus işlemi uygulanmış, daha sonra örnekler % 2'lik bazik fuksin solüsyonunda 24 saat bekletilmiştir. Örneklerden alınan kesitler stereomikroskop altında 30x büyütmede değerlendirme kriterlerine göre skorlanmıştır. Veriler SPSS V23 sürümü kullanılarak analiz edilmiştir. Üç grubun skorlarının karşılaştırılmasında Tek yönlü varyans analizi, ikili gruplara göre skorların karşılaştırılmasında ise Bağımsız iki örnek t testi kullanılmıştır. Sonuçlar yorumlanırken anlamlılık düzeyi p<0,05 olarak belirlenmiştir. Yapılan değerlendirmelerde RelyX U200 self adeziv rezin siman grubunda gözlenen mikrosızıntı değerlerinin en düşük, Ketac Cem Plus grubunda ise en yüksek olduğu tespit edilmiştir. Ancak grupların mikrosızıntı değerleri açısından başarı oranları karşılaştırıldığında, aralarında istatistiksel olarak anlamlı bir fark bulunmamıştır (p>0,05). Santral ve lateral dişlerin mikrosızıntı skorları arasında da istatistiksel olarak anlamlı farklılık olmadığı gözlenmiştir (p>0,05). Bu in vitro tez çalışmasında yapılan değerlendirmede, self adeziv rezin siman materyali diğer iki RMCİS materyaline göre daha düşük mikrosızıntı değeri göstermiş olsa da; aralarında istatistiksel olarak anlamlı farklılık bulunmamıştır. Anahtar Sözcükler: Zirkonyum, Kron, Dental simanlar, Süt dişleri, Simantasyonen_US
dc.description.abstractEvaluation of Microleakage for Different Cementation Materials Used in Prefabricated Zirconia Crowns The aim of this in vitro study was to evaluate and compare the microleakage of prefabricated zirconia crowns (NuSmile, Houston, TX, USA) when cemented with three different bonding cement to the extracted primary anterior teeth. In our study, two different RMGIC (Ketac Cem Plus, 3M ESPE, USA and FujiCEM Evolve, GC, Japan) and self adhesive resin cement (RelyX U200, 3M ESPE, USA) were used for the cementation of prefabricated zirconia crowns (NuSmile, TX, USA). Thirty six primary anterior teeth (18 central, 18 lateral) will be included in our study and randomly divided into three groups. Prefabricated zirconia crowns are cemented to the teeth prepared according to the manufacturer's instructions of the material in their group. Thermal cycle process was applied at 6000 cycles between 5 °C and 55 °C; Then the samples were kept in 2% basic fuchsin solution for 24 hours. The sections taken from the samples were scored according to the evaluation criteria at 30x magnification with stereomicroscope. Microleakage values determined for each group will be evaluated statistically. The data were analyzed in the SPSS V23 version. One-way analysis of variance was used for the comparison of the scores of the three groups, and the independent two-sample t test was used for the comparison of the scores of the paired groups. The significance level was determined as p<0.05. According to the results, the lowest microleakage values were found in the RelyX U200 self adhesive resin cement group, and the highest values were found in the Ketac Cem Plus group. When the microleakage values of the groups were compared, no statistically significant difference was found between them (p>0.05). No statistically significant difference was found between the microleakage scores of the central and lateral teeth (p>0.05). In the evaluation of this in vitro study, although the self-adhesive resin cement material showed a lower microleakage value than the other two RMCIS materials; There was no statistically significant difference between them. Keywords: Zirconium, Crown, Dental cements, Primary teeth, Cementationen_US
dc.language.isoturen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDiş Hekimliği = Dentistryen_US
dc.titlePrefabrı̇ke zirkonya kronlarda kullanılan farklı simantasyon materyallerı̇nin mıikrosızıntısının değerlendirilmesien_US
dc.title.alternativeEvaluation of microleakage for different cementation materials used in prefabricated zirconia crownsen_US
dc.typespecialtyThesisen_US
dc.contributor.departmentKırıkkale Üniversitesi, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.relation.publicationcategoryTezen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster