Yayın tarihi için Makale Koleksiyonu listeleme
Toplam kayıt 25, listelenen: 1-20
-
Clinical performance and biocompatibility of novel hyaluronan-based heparin-bonded extracorporeal circuits
(2005)We tested documented in vitro and ex vivo advantages of novel hyaluronan based heparin bonded extracorporeal circuits in a prospective randomized study. During the period from June until September 2005, 40 patients undergoing ... -
Comparison of polymethoxyethylacrylate-coated circuits with leukocyte filtration and reduced heparinization protocol on heparin-bonded circuits in different risk cohorts
(Sage Publications Ltd, 2006)Objectives: The relative benefits of strategic leukofiltration on polymer-coated and low-dose heparin protocol on heparin-coated circuits were studied across EuroSCORE patient risk strata for three different cohorts. ... -
Influence of hematocrit and pump prime on cerebral oxygen saturation in on-pump coronary revascularization
(Sage Publications Ltd, 2006)Background: The couplings between cerebral oxygenation (rSO(2)), on-pump hematocrit and circuit prime are explored in this study. Methods: Thirty-eight consecutive patients undergoing coronary revascularization with ... -
Clinical effects of leukofiltration and surface modification on post-cardiopulmonary bypass atrial fibrillation in different risk cohorts
(2007)Objective. A manifestation of inflammatory injury to the heart, atrial fibrillation (AF), ranks among the most frequent and potentially life-threatening post-operative complications. Methods. In a prospective randomized ... -
The relationship between the QT interval and autonomous and anthropometric features
(2007)Objectives: We investigated the effect of anthropometric and autonomous factors on the QT interval in both sexes. Study design: The study included 237 individuals (114 males, 123 females) who were asymptomatic and had no ... -
STS blood conservation guidelines: The role of leukocyte filtration
(Elsevier Science Inc, 2008)… -
Clinical impact and biomaterial evaluation of autologous platelet gel in cardiac surgery
(2008)We compared the clinical efficacy of autologous platelet gel (APG) and gelatine (CONT), including biomaterial evaluation. In a prospective, randomized, controlled trial, 64 patients undergoing complex coronary artery bypass ... -
Clinical and biomaterial evaluation of a new condensed dual-function extracorporeal circuit in reoperation for coronary artery bypass surgery
(Sage Publications Ltd, 2009)Purpose: This prospective, randomized study compared the clinical performance of three types of circuits: a newly introduced, fully-coated, interchangeable open-closed circuit with a dual configuration (hard shell with a ... -
Clinical evaluation of minimized extracorporeal circulation in high-risk coronary revascularization: impact on air handling, inflammation, hemodilution and myocardial function
(Sage Publications Ltd, 2009)Objective: We examined intraoperative microembolic signals (GME), inflammatory response, hemolysis, perioperative regional cerebral oxygen saturation (rSO(2)), myocardial protection and desorbed protein amount on oxygenator ... -
Clinical efficacy of leukofiltration on cardiopulmonary bypass related inflammatory response: Fact or Foe?
(Springer Basel Ag, 2009)The powerful precept of preoperative risk assessment has been applied to compare the efficacy of leukofiltration techniques for high-risk cohorts with the documentation of broad indicators of systemic inflammation. Forty ... -
Clinical and biomaterial evaluation of hyaluronan-based heparin-bonded extracorporeal circuits with reduced versus full systemic anticoagulation in reoperation for coronary revascularization
(Lippincott Williams & Wilkins, 2009)Objective This prospective randomized study compares full and reduced heparinization on novel hyaluronan-based heparin-bonded circuits vs. uncoated controls under challenging clinical setting including biomaterial evaluation. ... -
The impact of allogenic red cell transfusion and coated bypass circuit on the inflammatory response during cardiopulmonary bypass: A randomized study
(2009)Objective: This study is designed to determine and compare the effects of transfusion and coated circuits on the inflammatory response during cardiopulmonary bypass. Methods: Forty patients were randomized into two groups ... -
Clinical performance and biocompatibility of hyaluronan-based heparin-bonded extracorporeal circuits in different risk cohorts
(Oxford Univ Press, 2010)This prospective randomized study compares novel hyaluronan-based heparin-bonded circuits vs. uncoated controls across EuroSCORE patient risk strata including biomaterial evaluation. Over a two-year period, 90 patients ... -
Cardiopulmonary bypass technologies
(Woodhead Publ Ltd, 2010)Cardiopulmonary bypass (CPB) has revolutionized our ability to operate on the heart, great vessels, and aorta in addition to providing means of short-term support for reversible causes of cardiac and/or respiratory failure. ... -
Perioperative blood conservation strategies in pediatric patients undergoing open-heart surgery: impact of non-autologous blood transfusion and surface-coated extracorporeal circuits
(Sage Publications Ltd, 2011)Background: The aim of this study was to explore the relative clinical and biomaterial effects of blood transfusions (Tx) and novel low-prime, surface-coated circuitry on perioperative outcome in a pediatric population ... -
Clinical evaluation of leukocyte filtration as an alternative anti-inflammatory strategy to aprotinin in high-risk patients undergoing coronary revascularization
(Springer, 2012)Purpose The use of aprotinin in cardiac surgery is associated with overriding safety concerns. Therefore, there is increased research on alternatives. This study investigated the relative benefits of strategic leukofiltration ... -
Isolation, culturing and characterization of rat adipose tissue-derived mesenchymal stem cells: a simple technique
(Tubitak Scientific & Technical Research Council Turkey, 2012)In this study, our aim was to develop a new simple technique for isolation of mesenchymal stem cells from adipose tissue. For this purpose, mesenchymal stem cells were isolated from rat adipose tissue by using the primary ... -
Novel Ultrafiltration Technique for Blood Conservation in Cardiac Operations
(Elsevier Science Inc, 2013)Purpose. The performance characteristics and clinical outcome of a novel hemoconcentrator, the HemoSep (Brightwake, Nottingham, United Kingdom), for reusing salvaged blood postoperatively were evaluated. Description. HemoSep ... -
Clinical Manifestations in Patients with Segmental Hypoplasia of Great Saphenous Vein
(Kuwait Medical Assoc, 2017)Objectives: Segmental hypoplasia of the great saphenous vein (GSV) is a common condition which may cause chronic venous insufficiency. Despite the high incidence thereof, few studies have investigated GSV hypoplasia. We ... -
Mid-term results in the treatment of varicose veins with N-butyl cyanoacrylate
(Sage Publications Inc, 2017)Aim To present mid-term results of patients with varicose veins treated with N-butyl cyanoacrylate (VariClose (R)), a nontumescent endovenous ablation technique. Patients and method Endovenous ablation was performed on 180 ...