dc.contributor.author | Yalcinkaya F. | |
dc.contributor.author | Erbas A. | |
dc.contributor.author | Kizilkaplan E. | |
dc.date.accessioned | 2020-06-25T15:14:28Z | |
dc.date.available | 2020-06-25T15:14:28Z | |
dc.date.issued | 2010 | |
dc.identifier.isbn | 9780889868526 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/2115 | |
dc.description | Int. Assoc. Sci. Technol. Dev. (IASTED) -;Tech. Comm. Control;Int. Assoc. Sci. Technol. Dev. (IASTED) -;Tech. Comm. Intelligent Syst. Control;Control and Intelligent Systems | en_US |
dc.description | 12th IASTED International Conference on Control and Applications, CA 2010 -- 15 July 2010 through 17 July 2010 -- Banff, AB -- 89103 | en_US |
dc.description.abstract | Spinal Cord Stimulation is a physical therapy utilizing electrical impulses, pulses or patient specific waveforms to block pain. There has been a persistent search for a non-destructive, non-invasive, and effective way of relieving pain. Two different types of designs may be realized: Bed-side type [portable] or implantation/the surgical type. This work is made of three parts: Hardware (H/W) and software designs (S/W) and interface electronics introducing the system to external medical systems. The PIC18F452 Microcomputer based spinal cord stimulator generates three different types of signals: a variable saw-tooth wave with a minimum duty pulse width of 50 ?s, a variable triangular wave with a minimum duty pulse width of 100 ?s and a symmetrical variable impulse with a minimum duty pulse width of 25 ?s is described. Three parameters are software controlled, namely amplitude, frequency and duty-cycle. Hardware and software designs are explained. The frequency, duty-cycle and amplitudes of the pulses can be altered by software control making it a versatile stimulator. The stimulators architecture is designed to be modular and therefore its different blocks can be reused as standard building blocks. | en_US |
dc.language.iso | eng | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Medical instrumentation | en_US |
dc.subject | Microcomputer | en_US |
dc.subject | Multichannel | en_US |
dc.subject | Software control | en_US |
dc.subject | Spinal cord stimulator | en_US |
dc.title | The design and construction of a portable multichannel spinal cord stimulator based on pic18f452 microcontroller | en_US |
dc.type | conferenceObject | en_US |
dc.contributor.department | Kırıkkale Üniversitesi | en_US |
dc.identifier.startpage | 444 | en_US |
dc.identifier.endpage | 450 | en_US |
dc.relation.journal | Proceedings of the 12th IASTED International Conference on Control and Applications, CA 2010 | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |