dc.description.abstractIn this study, acrylic hydrogel copolymer membrane was synthesized from 2-hydroxyethylmethacrylate (HEMA) and glycidyl methacrylate (GMA) monomers. The pol ethylenimine polymer was then grafted onto membrane surface (poly(HEMA-co-GMA)-PEI). A dye-ligand (i.e., Cibacron Blue F3GA) was then covalently immobilized on the membrane through the amino groups of the polyethylenimine molecules (poly(HEMA-co-GMA)-PEI-CB). Both affinity membranes were used for the removal of bilirubin (BR) from aqueous solutions and human serum. The effects of pH, ionic strength, temperature and initial BR concentration on the adsorption capacity of both affinity membranes were investigated in a batch system. Separation of BR from human serum was also investigated in a batch system. Experimental data indicate that poly(HEMA-co-GMA)-PEI affinity membrane shows more adsorption capacity to BR than that of the poly(HEMA-co-GMA)-PEI-CB membrane, which may be explained on the basis of opposite charge on both PEI and BR. The BR adsorption on the poly(HEMA-co-GMA)-PEI and poly(HEMA-co-GMA)-PEI-CB affinity membrane did not well described by the Langmuir model, but obeyed the Freundlich isotherm model. The poly(HEMA-co-GMA)-PEI and poly(HEMA-co-GMA)-PEI-CB affinity membranes are stable when subjected to sanitization with sodium hydroxide after repeated adsorption-desorption cycles. (c) 2005 Elsevier B.V. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevier Science Bven_US
dc.relation.isversionof10.1016/j.colsurfa.2005.05.020en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectbilirubinen_US
dc.subjectPEIen_US
dc.subjectgraftingen_US
dc.subjectadsorptionen_US
dc.subjectmembranesen_US
dc.subjecthydrogelen_US
dc.subjectcontact angleen_US
dc.titleCharacterization of polyethylenimine grafted and Cibacron Blue F3GA immobilized poly (hydroxyethylmethacrylate-co-glycydylmethacrylate) membranes and application to bilirubin removal from human serumen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume264en_US
dc.identifier.issue1-3en_US
dc.identifier.startpage195en_US
dc.identifier.endpage202en_US
dc.relation.journalColloids And Surfaces A-Physicochemical And Engineering Aspectsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record