Basit öğe kaydını göster

dc.contributor.authorOzgul, Ozkan
dc.contributor.authorKocyigit, Ismail Doruk
dc.date.accessioned2020-06-25T18:29:44Z
dc.date.available2020-06-25T18:29:44Z
dc.date.issued2018
dc.identifier.citationclosedAccessen_US
dc.identifier.issn2157-9083
dc.identifier.issn2157-9091
dc.identifier.urihttps://doi.org/10.1166/jbt.2018.1737
dc.identifier.urihttps://hdl.handle.net/20.500.12587/7443
dc.descriptionWOS: 000429609000006en_US
dc.description.abstractObjective: The aim of this study is to compare the stress distribution of three different implant macro design applied with allogeneic cancellous bone rings using three dimensional finite element analyses. Material and Methods: Finite element models of maxilla and mandible that augmented with allogeneic bone ring graft with implants were created. Vertical force of 100 N and oblique force of 100 N at 45 degrees angle were applied to three different (variable thread, cylindrical, standard thread) macro design implants. Results: Stress concentrations in the conjunction of neck of the implant and allogeneic bone ring were higher than other areas. The highest calculated values of Von Misses stresses were observed in standard thread implant with oblique loading in mandible model. In all models the highest stress values were greater for oblique loading compare to vertical loading. Discussion: Implant macro designs shows different distributions to implanted bone or graft. It should be considered when choosing an implant in the cases augmented with allogeneic cancellous bone ring.en_US
dc.description.sponsorshipKirikkale University Scientific Research Project Department [2015/104]en_US
dc.description.sponsorshipThis study supported by Kirikkale University Scientific Research Project Department. Project No: 2015/104.en_US
dc.language.isoengen_US
dc.publisherAmer Scientific Publishersen_US
dc.relation.isversionof10.1166/jbt.2018.1737en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAllogeneic Bone Graften_US
dc.subjectImplant Macro Designen_US
dc.subjectFinite Element Analysisen_US
dc.titleChoosing Implant Type for Using with Allogeneic Bone Ring Graft: Guidance of Stress Analysis-Part Ien_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume8en_US
dc.identifier.issue2en_US
dc.identifier.startpage190en_US
dc.identifier.endpage196en_US
dc.relation.journalJournal Of Biomaterials And Tissue Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US