Ciftci, HakanTestereci, Hasan NurOktem, Zeki2020-06-252020-06-252013closedAccess1023-19351608-3342https://doi.org/10.1134/S1023193513010151https://hdl.handle.net/20.500.12587/5411Conducting poly(2-aminothiazole) (PAT) films were electrodeposited on a platinum disc electrode surface by constant potential electrolysis of 2-aminothiazole (AT) for the stripping voltammetric determination of Ag(I). Ag(I) was preconcentrated on the polymer matrix by dipping the modified Pt electrode (PAT-Pt electrode) into Ag(I)(aq) solution. Effects of the film thickness, reduction potential, pH, preconcentration time, Ag(I) concentration and the interference of some other metal ions on the oxidation peak current of silver were studied. Cu(II) interference observed to be significant for the stripping voltammetric determination of Ag(I). The detection limit was calculated on the basis of signal to noise ratio of 3 as 2 x 10(-7) mol L-1.eninfo:eu-repo/semantics/closedAccesspoly(2-aminothiazole)conducting polymermodified electrodesilver determinationstripping voltammetryPreconcentration and electroanalysis of silver at pt electrode modified with poly(2-aminothiazole)Article49121160116410.1134/S10231935130101512-s2.0-84891167178Q4WOS:000328219800008Q4