Basit öğe kaydını göster

dc.contributor.authorKocaman, Ayse Abit
dc.contributor.authorArslan, Saniye Aydogan
dc.contributor.authorUgurlu, Kubra
dc.contributor.authorKirmaci, Zekiye Ipek Katirci
dc.contributor.authorKeskin, E. Dilek
dc.date.accessioned2021-01-14T18:08:54Z
dc.date.available2021-01-14T18:08:54Z
dc.date.issued2021
dc.identifier.issn1052-3057
dc.identifier.issn1532-8511
dc.identifier.urihttps://doi.org/10.1016/j.jstrokecerebrovasdis.2020.105462
dc.identifier.urihttps://hdl.handle.net/20.500.12587/12494
dc.descriptionaydogan arslan, saniye/0000-0001-5470-9849; abit kocaman, ayse/0000-0002-6694-3015en_US
dc.descriptionWOS:000601309800040en_US
dc.descriptionPubMed: 33197801en_US
dc.description.abstractObjectives: The 3-m backward walk test (3MBWT) is used to evaluate neuromuscular control, proprioception, protective reflexes, fall risk and balance. The aim of our study was to reveal the test-retest reliability and validity of the 3MBWT in stroke patients. Materials and Methods: This study included a total of 41 stroke patients [age 59 (35-78) years]. 3MBWT, Berg Balance Scale (BBS), Timed Up and Go test (TUG) were applied to the patients. The second evaluation (retest) was carried out by the same physiotherapist two days following the first evaluation (test) in order to measure test-retest reliability. Results: Cronbach's alpha coefficient was found to be 0.974 (excellent). For intra-rater agreement, the ICC values in the individual test were 0.985. The SEM value was 1.11 sec, the MDC value was found to be 1.57 sec. A moderate correlation was revealed between the 3 m-backward walking speed and BBS (r: -0.691, p: 0.001) and TUG (r: 0.849, p: 0.001). Conclusions: The 3MBWT was observed to be valid and reliable in stroke individuals. It is an effecive and reliable tool for measuring dynamic balance and falls in stroke.en_US
dc.language.isoengen_US
dc.publisherELSEVIERen_US
dc.relation.isversionof10.1016/j.jstrokecerebrovasdis.2020.105462en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectFallsen_US
dc.subjectStrokeen_US
dc.subjectBackward walkingen_US
dc.subject3MBWTen_US
dc.subjectValidityen_US
dc.subjectReliabilityen_US
dc.titleValidity and Reliability of The 3-Meter Backward Walk Test in Individuals with Strokeen_US
dc.typearticleen_US
dc.contributor.departmentKKÜen_US
dc.identifier.volume30en_US
dc.identifier.issue1en_US
dc.relation.journalJOURNAL OF STROKE & CEREBROVASCULAR DISEASESen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US