dc.descriptionPubMed: 32856885en_US
dc.description.abstractBackground: Considering the critical role of early diagnosis and management of acute ischemic stroke, biomarkers that can reliable assist in the diagnosis are still needed. These biomarkers should rapidly analyze, have high specificity for brain damage, and be available in the emergency settings for early diagnosis and exclusion of other conditions that mimic acute ischemic stroke. Soluble tumor necrosis factor-like weak inducer of apoptosis, a protein involved in the regulation of several biological functions, could be a potential acute ischemic stroke biomarker. Aims: To investigate the diagnostic value of soluble tumor necrosis factor-like weak inducer of apoptosis in patients with acute ischemic stroke and examine the relationship between ischemic area volume determined at diffusion-weighted magnetic resonance imaging and soluble tumor necrosis factor-like weak inducer of apoptosis. Study Design: A prospective, case-control study. Methods: This case-control prospective study included 36 patients with acute ischemic stroke and 36 healthy volunteers. Information on age, sex, presence of chronic disease, neurological examination findings, times of presentation to the emergency department after acute ischemic stroke, soluble tumor necrosis factor-like weak inducer of apoptosis levels, ischemic area volumes at diffusion-weighted magnetic resonance imaging, and 6-month mortality rates after stroke were recorded. The results were analyzed on SPSS 22.0 software (SPSS Inc., Chicago, IL, USA), and p<0.05 was considered statistically significant. Results: A soluble tumor necrosis factor-like weak inducer apoptosis cut-off value of 995.5 pg/mL exhibited a sensitivity of 80.5% and a positive predictive value of 82.5% with an area under the curve of 0.84 (95% confidence interval: 0.74-0.94; p<0.001). The mean soluble tumor necrosis factor-like weak inducer of apoptosis level - in the acute ischemic stroke group (1968.08=1441.99 mu g/L) were significantly higher than those in the control group (704.81 +/- 291.72 14,1) (p<0.001). No correlation was observed between soluble tumor necrosis factor-like weak inducer of apoptosis levels and ischemic area volume measured at diffusion-weighted magnetic resonance imaging (r=-0.008; p=0.07). The mean ischemic area volume was 505.68 +/- 381.10 and 60.96=80.89 mm(3) in the nonsurviving and surviving patients, respectively (p =.002). Conclusion: Soluble tumor necrosis factor-like weak inducer of apoptosis can be used in the diagnosis of acute ischemic stroke. However, it is inconclusive in estimating ischemic area volume and early mortality following acute ischemic stroke. Ischemic area volume measured at diffusion-weighted magnetic resonance imaging is a marker of poor prognosis and can be used in predicting early mortality.en_US
dc.description.sponsorshipKirikkale University Scientific Research ProjectKirikkale University [2015/11]en_US
dc.description.sponsorshipThis work is funded by Kirikkale University Scientific Research Project support (project no. 2015/11).en_US
dc.language.isoengen_US
dc.publisherGALENOS YAYINCILIKen_US
dc.relation.isversionof10.4274/balkanmedj.galenos.2020.2020.2.45en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIschemic area volumeen_US
dc.subjectischemic strokeen_US
dc.subjectmagnetic resonance imagingen_US
dc.subjectsTWEAKen_US
dc.titleThe Diagnostic Value of sTWEAK in Acute Ischemic Strokeen_US
dc.typearticleen_US
dc.contributor.departmentKKÜen_US
dc.identifier.volume37en_US
dc.identifier.issue6en_US
dc.identifier.startpage336en_US
dc.identifier.endpage340en_US
dc.relation.journalBALKAN MEDICAL JOURNALen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster