dc.contributor.author | Kayaci, Selim | |
dc.contributor.author | Bas, Orhan | |
dc.contributor.author | Beyazal Celiker, Fatma | |
dc.contributor.author | Ucuncu, Yilmaz | |
dc.contributor.author | Arslan, Yusuf Kemal | |
dc.contributor.author | Ozveren, Mehmet Faik | |
dc.contributor.author | Aykol, Sukru | |
dc.date.accessioned | 2021-01-14T18:11:01Z | |
dc.date.available | 2021-01-14T18:11:01Z | |
dc.date.issued | 2020 | |
dc.identifier.citation | Kayacı, S., Baş, O., Beyazal Çeliker, F., Üçüncü, Y., Arslan, Y. K., Özveren, M. F., & Aykol, Ş. (2018). Comparison of thalamus volume on magnetic resonance and cadaveric section images and its importance in the context of deep brain stimulation. Turkish Neurosurgery, 1(1), 5–10. | en_US |
dc.identifier.issn | 1019-5149 | |
dc.identifier.uri | https://doi.org/10.5137/1019-5149.JTN.24530-18.2 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/12855 | |
dc.description | ARSLAN, YUSUF KEMAL/0000-0003-1308-8569 | en_US |
dc.description | WOS:000551172600004 | en_US |
dc.description | PubMed: 30649832 | en_US |
dc.description.abstract | AIM: To measure and to compare the volume of thalamus using magnetic resonance imaging (MRI) and the anatomical sections. MATERIAL and METHODS: In this study, 13 brain specimens were used. First, the images were taken in 3 mm sections on MRI, the thickness of the thalamus was measured. Subsequently, 4 mm coronal sections were prepared using amicrotome. The thalamic volumes calculated from cadaveric specimens were compared with the measurements obtained using MRI. RESULTS: On MRI, the mean thalamic volumes on the right and left hemispheres were found to be 5843.4. 361.6 mm(3) and 5377.0 +/- 666.2 mm(3) respectively. The mean volumes of the cadaveric sections were 5610.8 +/- 401.3 mm(3) on the right side and 5618.5 +/- 604.1 mm(3) on the left hemisphere. No statistically significant difference was found between the volume calculated from MRI and that obtained from the cadaveric section (p<0.05). CONCLUSION: This study shows a correlation between measurement of thalamus volume based on MRI and those calculated from anatomical sections. Our findings support the reliability of DBS procedures using MRI and stereotactic method. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | TURKISH NEUROSURGICAL SOC | en_US |
dc.relation.isversionof | 10.5137/1019-5149.JTN.24530-18.2 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Cadaver | en_US |
dc.subject | Deep brain stimulation | en_US |
dc.subject | Magnetic Resonance Imaging | en_US |
dc.subject | Planimetry technique | en_US |
dc.subject | Thalamus | en_US |
dc.title | Comparison of Thalamus Volume on Magnetic Resonance and Cadaveric Section Images | en_US |
dc.type | article | en_US |
dc.contributor.department | KKÜ | en_US |
dc.identifier.volume | 30 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 491 | en_US |
dc.identifier.endpage | 500 | en_US |
dc.relation.journal | TURKISH NEUROSURGERY | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |