Basit öğe kaydını göster

dc.contributor.authorKaya T.
dc.contributor.authorBüyükkoçak U.
dc.contributor.authorBaşar H.
dc.contributor.authorSağsöz N.
dc.date.accessioned2020-06-25T15:14:13Z
dc.date.available2020-06-25T15:14:13Z
dc.date.issued2008
dc.identifier.issn13000012
dc.identifier.urihttps://hdl.handle.net/20.500.12587/2051
dc.descriptionPubMed: 19117154en_US
dc.description.abstractAnalgesic techniques after c-section must be effective producing early mobilisation to enable mothers to care effort their babies. In this study, the comparison of ropivacaine 0.2% alone, with ropivacaine 0.2%+sufentanil 0.75 microg mL-1 for patient controlled epidural analgesia (PCEA) was aimed. Fifty women (ASA-I) were enrolled in the study. All patients had combined spinal-epidural anaesthesia. Infusion of analgesic solutions was started when sensory level decreased by two dermatome levels. The patients randomly assigned, into two groups (n=25). In Group-I, ropivacaine 0.2% and sufentanil 0.75 microg mL-1, in Group-II, ropivacaine 0.2% alone were applied (bolus 1.25 mL, lockout 30 min, with 2.5 mL h-1 background infusion). Pain (Visual Analog Scale), motor blockage (Bromage scale) and sedation (Four point scale) were evaluated during 24 hours after Caesarean, using the scales of visual analogue, bromage, and four-point, respectively. Haemodynamic and respiratory parameters, side effects, total drug consumption and additional analgesic need, were recorded. Statistical analysis included student-t, chi-square, and Mann Whitney U tests. There was no difference in demographic data, sedation scores, haemodynamic and respiratory parameters, between the groups. Motor block and pain scores were significantly higher in Group-II than in Group-I at 2 and 4. h. Total drug consumption was 65.24+/-4.20 mL for Group-I and 81.1+/-6.44 mL for Group-II, (P<0.05). Four patients in Group-I and 21 patients in Group-II received additional analgesic. Pruritus was observed more frequently in Group-I. The addition of sufentanil 0.75 microg mL-1 to ropivacaine 0.2% for PCEA after Caesarean led to more effective analgesia and less motor weakness when compared to ropivacaine 0.2% alone, especially during early postoperative period.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleComparison of epidural ropivacaine 0.2% and ropivacaine 0.2% in combination with sufentanil 0.75 microg mL-1 for postcaesarean analgesia.en_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume20en_US
dc.identifier.issue4en_US
dc.identifier.startpage30en_US
dc.identifier.endpage37en_US
dc.relation.journalAğri : Ağri (Algoloji) Derneği'nin Yayin organidir = The journal of the Turkish Society of Algologyen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster