Basit öğe kaydını göster

dc.contributor.authorDemir K.
dc.contributor.authorBayraktar Y.
dc.date.accessioned2020-06-25T15:18:20Z
dc.date.available2020-06-25T15:18:20Z
dc.date.issued2020
dc.identifier.issn21786011
dc.identifier.urihttps://doi.org/10.14295/bds.2020.v23i2.1948
dc.identifier.urihttps://hdl.handle.net/20.500.12587/2697
dc.description.abstractObjectives: This study aims to evaluate the degree of conversion (DC) and microlekage scores of three different composite resins polymerized with a LED curing device in standard and extra-power mode. Material and Methods: One bulk-fill (Tetric EvoCeram Bulk-Fill – TECBF) and two conventional composite materials (Clearfil Majesty Posterior – CMP and Tetric EvoCeram – TEC) were evaluated. A total of 30 specimens were prepared for six groups (N = 5). These groups were polymerized with a LED curing device as follows: TECBF-6: 3200mW/cm2 for six seconds, TECBF-20: 1000mW/cm2 for 20 seconds, CMP-6: 3200mW/cm2 for six seconds, CMP-20: 1000mW/cm2 for 20 seconds, TEC-6: 3200mW/cm2 for six seconds, TEC-20: 1000 mW/cm2 for 20 seconds. After 24 hours of water storage, DC was measured by Raman spectroscopy. Microleakage scores of the six groups were bonded to various adhesive systems (Clearfil SE Bond or Adhese Bond Universal) were also evaluated at Class II box cavities (N = 10). Results: While the highest DC was found at the top (TECBF-20= 79.92% and TECBF-6= 79.02%) and bottom surfaces (TECBF-20 = 68.94% and TECBF-6= 71.04%) for TECBF groups, TEC groups (TEC-20top = 59.06%, TEC-6top=49.66%, TEC-20bottom = 43.72% and TEC-6bottom= 40.68%) showed the lowest DC for the both surfaces (p < 0.05). Polymerization of materials in standard or extra-power mode was similar to DC (p > 0.05). Microleakage scores were found to be similar (p > 0.05). Conclusion: According to the results of the study, different power densities of LED curing light did not affect the DC of composite resins and microleakage values of restorations at small Class II cavities. © 2020, Universidade Estadual Paulista, Institute of Science and Technology of Sao Jose dos Campos. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherUniversidade Estadual Paulista, Institute of Science and Technology of Sao Jose dos Camposen_US
dc.relation.isversionof10.14295/bds.2020.v23i2.1948en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBulk-fill compositeen_US
dc.subjectDegree of conversionen_US
dc.subjectLED curing deviceen_US
dc.subjectMicroleakageen_US
dc.subjectRaman spectroscopyen_US
dc.titleEvaluation of microleakage and the degree of conversion of three composite resins polymerized at different power densitiesen_US
dc.title.alternativeAvaliação da microinfiltração e do grau de conversão de três resinas compostas polimerizadas em diferentes densidades de potênciaen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume23en_US
dc.identifier.issue2en_US
dc.relation.journalBrazilian Dental Scienceen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster