Basit öğe kaydını göster

dc.contributor.authorSevil, Tugce
dc.contributor.authorBaran, Mehmet
dc.contributor.authorBilir, Turhan
dc.contributor.authorCanbay, Erdem
dc.date.accessioned2020-06-25T17:52:00Z
dc.date.available2020-06-25T17:52:00Z
dc.date.issued2011
dc.identifier.citationclosedAccessen_US
dc.identifier.issn0950-0618
dc.identifier.issn1879-0526
dc.identifier.urihttps://doi.org/10.1016/j.conbuildmat.2010.06.096
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5054
dc.descriptionBilir, Turhan/0000-0003-0317-026X; Canbay, Erdem/0000-0001-6798-0144; Baran, Mehmet/0000-0001-6674-7308en_US
dc.descriptionWOS: 000285893300060en_US
dc.description.abstractThe objective of this research was to develop an economical, structurally effective, and practically applicable steel fiber reinforced mortar (SFRM) which could be applied onto the hollow brick infills of a reinforced concrete (RC) structure. Masonry walls were almost converted into strong and rigid infills with the application of SFRM. Two different mix proportions were produced with the composition of Portland cement, fine aggregate, water, and plasticizer or bonding agent as the chemical admixture. Tests were carried out to determine the optimum steel fiber content (1%, 2%, or 4% by volume) and to clarify the use of plasticizer or bonding agent in the mortar in the context of sticking ability, flexural, compressive, and adhesion strengths. As a result, mortar with plasticizer and 2% steel fiber (by volume) came out to be the optimum mortar mixture as strengthening material. The performance of RC frame strengthened with SFRM containing plasticizer and 2% steel fiber by volume was compared to those of the hollow brick infilled RC frame without strengthened mortar and the hollow brick infilled RC frame with reference mortar. It was observed that the specimen strengthened with the optimum mortar mix satisfied the target objectives of this study. (C) 2010 Elsevier Ltd. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevier Sci Ltden_US
dc.relation.isversionof10.1016/j.conbuildmat.2010.06.096en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectSteel fiber reinforced mortaren_US
dc.subjectHollow brick infill wallen_US
dc.subjectReinforced concreteen_US
dc.subjectStrengtheningen_US
dc.titleUse of steel fiber reinforced mortar for seismic strengtheningen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume25en_US
dc.identifier.issue2en_US
dc.identifier.startpage892en_US
dc.identifier.endpage899en_US
dc.relation.journalConstruction And Building Materialsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster