Basit öğe kaydını göster

dc.contributor.authorGunebakmaz, Ozgur
dc.contributor.authorCelik, Ahmet
dc.contributor.authorInanc, M. Tugrul
dc.contributor.authorDuran, Mustafa
dc.contributor.authorKarakaya, Ekrem
dc.contributor.authorTulmac, Murat
dc.contributor.authorTopsakal, Ramazan
dc.date.accessioned2020-06-25T17:52:05Z
dc.date.available2020-06-25T17:52:05Z
dc.date.issued2011
dc.identifier.citationGünebakmaz, O., Celik, A., Inanc, M. T., Duran, M., Karakaya, E., Tulmac, M., Akpek, M., Sarli, B., Ergin, A., & Topsakal, R. (2011). Copeptin level and copeptin response to percutaneous balloon mitral valvuloplasty in mitral stenosis. Cardiology, 120(4), 221–226.en_US
dc.identifier.issn0008-6312
dc.identifier.issn1421-9751
dc.identifier.urihttps://doi.org/10.1159/000335888
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5072
dc.descriptionWOS: 000301616800010en_US
dc.descriptionPubMed: 22343496en_US
dc.description.abstractWe aimed to investigate copeptin levels in mitral stenosis (MS) patients and the behavior of copeptin after hemodynamic improvement achieved by percutaneous balloon mitral valvuloplasty (PBMV). The study involved 29 consecutive symptomatic patients with moderate to severe rheumatic MS who underwent PBMV. Twenty-eight age- and gender-matched healthy volunteers composed the control group. Blood samples for copeptin were obtained immediately before and 24 h after PBMV, centrifuged, then stored at -70 degrees C until assayed. The copeptin level of the patient group was statistically different from that of the control group (61.8 +/- 34.4 and 36.8 +/- 15.2 pg/ml, respectively; p = 0.001). PBMV resulted in a significant increase in mitral valve area and a significant decrease in transmitral gradient as well as systolic pulmonary artery pressure. While hemodynamic relief was obtained, we detected a statistically significant decline in copeptin levels 24 h after PBMV compared to the baseline levels (from 61.8 +/- 34.4 to 44.1 +/- 18.2 pg/ml; p = 0.004). Copyright (C) 2012 S Karger AG, Baselen_US
dc.language.isoengen_US
dc.publisherKargeren_US
dc.relation.isversionof10.1159/000335888en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMitral stenosisen_US
dc.subjectPercutaneous balloon mitral valvuloplastyen_US
dc.subjectCopeptinen_US
dc.titleCopeptin Level and Copeptin Response to Percutaneous Balloon Mitral Valvuloplasty in Mitral Stenosisen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume120en_US
dc.identifier.issue4en_US
dc.identifier.startpage221en_US
dc.identifier.endpage226en_US
dc.relation.journalCardiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster