Basit öğe kaydını göster

dc.contributor.authorCiftci, Hakan
dc.contributor.authorTamer, Ugur
dc.contributor.authorMetin, Aysegul U.
dc.contributor.authorAlver, Erol
dc.contributor.authorKizir, Nevin
dc.date.accessioned2020-06-25T18:12:14Z
dc.date.available2020-06-25T18:12:14Z
dc.date.issued2014
dc.identifier.citationclosedAccessen_US
dc.identifier.issn0021-891X
dc.identifier.issn1572-8838
dc.identifier.urihttps://doi.org/10.1007/s10800-014-0676-0
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5823
dc.descriptionTamer, Ugur/0000-0001-9989-6123en_US
dc.descriptionWOS: 000334178900003en_US
dc.description.abstractThis study outlines a new sensing platform based on glassy carbon electrodes modified by gold nanoparticles (AuNPs) for the determination of heavy metal. A glassy carbon electrode was modified by chitosan stabilized AuNPs. AuNPs were prepared by reducing gold salt with a polysaccharide chitosan. Here, chitosan acted as a reducing/stabilizing agent. The AuNPs were characterized with UV-Visible absorption spectroscopy, Fourier transform infrared spectroscopy, and transmission electron microscopy. Chitosan covered AuNPs were immobilized on the glassy carbon electrode for the determination of Cu (II) in aqueous solutions. The electrochemical determination of Cu (II) ions was performed using the differential pulse voltammetry technique. Some parameters for Cu (II) determination, such as pH, preconcentration time and electrolysis potential of Cu (II), were optimized. The detection limit was calculated as 5 x 10(-9) mol L-1 by means of the 3:1 current-to-noise ratio. The interference of Cr(III), Fe(II), Ni(II), Pb(II), Mg(II), Zn(II), Ba(II) ions was investigated and showed a negligible effect on the electrode response. Recovery studies were carried out using tap water.en_US
dc.description.sponsorshipKirikkale UniversityKirikkale University [2013/86]en_US
dc.description.sponsorshipThe authors gratefully acknowledge the financial support from Kirikkale University. Research fund through grant no: 2013/86.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.relation.isversionof10.1007/s10800-014-0676-0en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGold nanoparticlesen_US
dc.subjectChitosanen_US
dc.subjectHeavy metal sensoren_US
dc.subjectCu (II) determinationen_US
dc.subjectElectrochemical sensoren_US
dc.titleElectrochemical copper (II) sensor based on chitosan covered gold nanoparticlesen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume44en_US
dc.identifier.issue5en_US
dc.identifier.startpage563en_US
dc.identifier.endpage571en_US
dc.relation.journalJournal Of Applied Electrochemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster