Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Atala, Mustafa H." seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Comparison of radiopacity of current restorative CAD/CAM blocks with digital radiography
    (Wiley, 2019) Atala, Mustafa H.; Atala, Nagehan; Yegin, Elif; Bayrak, Seval
    Objective While the radiopacity of restorative material affects the radiographic diagnosis of the teeth, there is no data about the radiopacity of current restorative computer-aided design (CAD)/computer-aided manufacturing (CAM) materials. Therefore, the present study compared the radiopacity values of current restorative CAD/CAM blocks to facilitate the material choice within such a wide variety of materials. Materials and Methods Specimens were prepared from 13 different restorative CAD/CAM blocks to compare with enamel and dentin. The specimens placed on the occlusal phosphor plate were imaged with aluminum step wedge and tooth section. The radiopacity values were calculated using the Image J program. The radiopacity values of the specimens were converted to mmAl values with the Curve Expert 1.4 program. Results The difference between the radiopacity values of dentin and e.max CAD was not significant, however, they exhibited a significant difference from the other 14 groups (P < .05). Enamel and Obsidien, Suprinity, and Celtra Duo had greater radiopacity values with significant differences from the other 12 materials whereas the difference within these groups was not significant (P > .05). Conclusions The evaluated restorative CAD/CAM materials have significantly different radiopacity values. Among these permanent restoration blocks, the highest radiopacity value was observed in Celtra Duo, the lowest in Block HC.

| Kırıkkale Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kırıkkale Üniversitesi, Kırıkkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim