Yazar "Polat, Serdar" seçeneğine göre listele
Listeleniyor 1 - 3 / 3
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Effects of Implant Angulations and Attachment Configurations on the Retentive Forces of Locator Attachment-Retained Overdentures(Quintessence Publishing Co Inc, 2014) Uludag, Bulent; Polat, Serdar; Sahin, Volkan; Comut, Ali AlperPurpose: The aim of this study was to evaluate the effects of different implant angulations and attachment configurations on the retentive forces of locator attachment-retained overdentures over a simulated time period of 6 months. Materials and Methods: Two acrylic resin models (models 1 and 2) were fabricated to represent an edentulous mandible. In model 1, the midline implant (in the central region) was vertical and the other two implants (in the canine regions) were 20 degrees divergent from the midline, reaching a total divergence of 40 degrees. In model 2, all three implants were vertically oriented, perpendicular to the occlusal plane and parallel to each other. Three-point vertical pull-out forces were employed in a universal testing machine at a constant crosshead speed of 50 mm/min after overdenture construction and a simulation of 6 months of repeated insertions/removals of the overdenture. Locator attachments with different male combinations and bar and clip attachments were tested in model 1. Clear locator attachments and bar and clip attachments were tested in model 2 and served as controls. Results: The initial retentive forces of all attachments in both models ranged from 26.58 to 62.05 N, whereas the initial retentive forces of the attachments for only model 1 ranged from 49.58 to 62.05 N. The highest retention value was recorded for clear green locator attachments and the lowest for hader bar yellow clip attachments. Locator attachments showed higher retention values than hader bar yellow clip attachments. Conclusion: All attachment systems demonstrated a decrease in retention over time. Locator attachments provided better retention than hader bar yellow clip attachments. The highest retention values were obtained when green male locators were used in combination with male attachments.Öğe Replacement of a Lost Removable Partial Dental Prosthesis Using Ball-Attachment Analogs: A Clinical Report(Wiley-Blackwell, 2011) Uludag, Bulent; Sahin, Volkan; Polat, SerdarAttachment-retained removable partial dental prostheses (RPDPs) may be lost. Although in such situations, the RPDP should be remade, no method has yet been described for replacing lost attachment-retained RPDPs. This report describes a method for fabrication of a replacement for a lost maxillary RPDP using ball-attachment analogs.Öğe A Technique for Constructing a New Maxillary Overdenture to a Nonretrievable Implant Connecting Bar(Allen Press Inc, 2013) Uludağ, Bülent; Polat, Serdar; Şahin, Volkan; Göktuğ, GürkanThe most frequent mechanical complications of the bar-implant-retained overdentures are loosening of the bar screws and the need to reactivate the retentive clips. This article describes a technique to construct a new maxillary overdenture to a nonretrievable round-profile implant connecting bar with 2 distally placed attachments. The retainer round-profile bar was nonretrievable due to a worn retaining screw head. Attachment transfer analogs are used to transfer the position of the attachments to the master cast. The technique allows the clinician to construct new overdentures without the need for removal of the implant connecting bar. Reduced chairside time, reduced treatment cost, and increased patient satisfaction are the major advantages of the technique.