Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Zorba, Y. Orcun" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • Yükleniyor...
    Küçük Resim
    Öğe
    Quality of curing in relation to different light sources by measuring hardness, degree of conversion and depth of cure
    (Maney Publishing, 2009) Zorba, Y. Orcun; Bayindir, Y. Z.; Turgut, H.; Yildiz, M.
    This study was to determine the quality of curing of second generation light emitting diode (LED-II) compared to a first generation LED (LED-I) and conventional halogen (quartz tungsten halogen) light curing unity by measuring depth of cure, degree of polymerisation and surface hardness. Filtek Z-250 hybrid composite resin (3M-ESPE, Germany), with shade A2, was used in this study. One quartz tungsten halogen/light curing unit (LCU) (Hilux, Benlioglu Dental, Turkey), one LED-I-LCU unit (Elipar Freelight 3M-ESPE, Germany) and one LED-II-LCU (Elipar Freelight, 3M-ESPE, Germany) were used for polymerisation of the composite resin. The depth of cure was obtained with scrape test, degree of cure was measured with Fourier transform infrared spectrometer (Spectrum-One, Perkin-Elmer, USA) and surface hardness was calculated with surface hardness tester (Micromet-2001, Buehler, Dusseldorf, Germany). The data were analysed by Kruskal Wallis and Mann Whitney-U. The polymerisation depth of LED-I-LCU was significantly lower than that of the other LCUs (p<0.05). However, no significant differences were obtained among all tested systems in point of degree of cure and surface hardness at 2 mm depth. Within the limitations of this study, although LED-I showed lower depth of cure, all tested systems appear suitable for routine clinical practice for polymerisation of the composite resin.

| Kırıkkale Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Kırıkkale Üniversitesi, Kırıkkale, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim