Yazar "Zorba, Yahya Orçun" seçeneğine göre listele
Listeleniyor 1 - 5 / 5
Sayfa Başına Sonuç
Sıralama seçenekleri
Öğe Effects of Different Curing Units and Luting Agents on Push-out Bond Strength of Translucent Posts(Elsevier Science Inc, 2010) Zorba, Yahya Orçun; Erdemir, Ali; Türkyılmaz, Ali; Eldeniz, Ayce ÜnverdiIntroduction: The aim of this study was to evaluate the effects of different curing units and 2 luting cements on the push-out bond strength of a translucent fiber post. Methods: Thirty maxillary incisor roots were endodontically treated. Post spaces were prepared, and the smear layers were removed. Posts (FRC Postec Plus) were luted with either a self-etch cement (Panavia F 2.0) or a self-adhesive cement (Maxcem). Luting agents were then light-activated with a quartz-tungsten-halogen, a blue light emitting diode, or a plasma-arc curing unit. Roots/cemented posts were transversally sectioned from coronal to apical. Push-out tests were performed, and data were analyzed by using three-way analysis of variance and Tukey tests. Results: Push-out bond strengths were significantly affected by the type of luting agent (P < .05) and root region (P < .05). The type of light source used in curing did not affect push-out bond strengths (P > .05). Conclusions: Self-adhesive resin cement provided higher bond strength than the self-etch cement when smear layer was removed before the post cementation. The push-out bond strength in the apical portion of the root was significantly lower than in the coronal region. The use of different curing units in the photoirradiation of dual-cured resin cement did not affect the retention of the fiber post as a result of the limited light transmission capability of this post. (J Endod 2010;36:1521-1525)Öğe The effects of three different desensitizing agents on the shear bond strength of composite resin bonding agents(Elsevier Science Bv, 2010) Zorba, Yahya Orçun; Erdemir, Ali; Ercan, Ertuğrul; Eldeniz, Ayce Ünverdi; Kalaycıoğlu, Barış; Ülker, MustafaThe aim of this study was to evaluate the effects of three desensitizing agents on the shear bond strengths of four different bonding agents used to bond composite resin to dentin. A total of 160 extracted human molars were sectioned parallel to the occlusal plane under water cooling, polished and randomly divided into 4 groups of 40. Each group was treated with a different desensitizing agent (Tooth Mousse, Ultra-EZ, Cervitec Plus), except for an untreated control group. Each group was then randomly subdivided into 4 groups of 10, and a different dentin bonding agent (XP Bond, AdheSE, Adper Prompt L-pop, GBond) was applied to each group in order to bond the specimens to a resin composite (Gradia Direct) built up using a plastic apparatus. A Universal Testing Machine was used to measure the shear bond strength of each specimen. Statistical analysis was performed using one-way ANOVA and Tukey's tests. With the exception of the Control/AdheSE and Ultra-EZ/XP Bond groups, no statistically significant differences were found in the shear bond strength values of the groups tested. These findings suggest that the use of different desensitizing agents does not affect the shear bond strength of various adhesive systems used to bond resin composite to dentin. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.Öğe Farklı tipteki II. sınıf kavite dizaynı kullanılan dişlerin kırılma dirençlerinin değerlendirilmesi(2007) Ercan, Ertuğrul; Erdemir, Ali; Zorba, Yahya Orçun; Dallı, MehmetBu çalışmanın amacı; farklı yöntemlerle hazırlanan II. sınıf kavitelere uygulanan posterior restoratif materyallerin kırılma dayanıklılıklarının değerlendirilmesidir. Bu çalışmada 40 adet çürüksüz yeni çekilmiş insan premolar dişi kullanıldı. Dişler her bir grupta 10 adet diş olacak şekilde rastgele dört gruba ayrıldı. Grup 1 kontrol grubu olarak ayrıldı ve herhangi bir işlem uygulanmadı. Grup 2, 3 ve 4 teki dişlerde sırasıyla klasik sınıf II kavite, modifiye sınıf II kavite ve tünel kaviteler hazırlandı. Kavite preparasyonları hazırlandıktan sonra dişler posterior kompozit (Dentsply, Kontstanz, Germany) ile restore edildi. Örnekler Instron test cihazına bağlandı ve okluzal yüzeyleri kırılma görülene kadar 1mm/dk hızla sıkıştırma kuvvetlerine maruz bırakıldı. Örneklerin kırılması için gerekli olan sıkıştırma kuvvetleri Newton olarak kaydedildi. Elde edilen veriler tek yönlü varyans analizi ve Tukey testleri kullanılarak istatistiksel olarak analiz edildi. Her gruptaki örneklerin kırılması için gerekli ortalama kuvvetler şu şekilde belirlendi. Grup 1: 828.23118.21, Grup 2: 779.32139.99, Grup 3: 799.82117.26, Grup 4: 805.39108.68. Gruplar arasında istatistiksel olarak önemli bir farklılık bulunamadı (p0.05). Sonuç olarak dişlerin restorasyonunda farklı kavite dizaynlarının kullanılmasının dişlerin kırılma dayanımında etkili olmadığı bulundu.Öğe Reactions of connective tissue to self-etching/priming dentin bonding systems: oxidative stress, tumor necrosis factor a expression, and tissue reactions(Elsevier Taiwan, 2009) Zorba, Yahya Orçun; Yıldız, Mehmet; Yıldırım, Abdulkadir; Gürsan, Nesrin; Ercan, ErtuğrulBackground/purpose: Few data have been published concerning tissue and systemic responses to resinous dental materials. The aim of this study was to compare and evaluate the biocompatibility of four kinds of dental self-etching/priming adhesives by measuring tissue responses, local and systemic tumor necrosis factor (TNF) alpha expression, and oxidative stress parameters. Materials and methods: Eighty rats were equally divided into 10 groups. Four dental adhesives (Clearfil SE Bond, iBond, Clearfil Protect Bond, and Adper Prompt L-Pop) were applied to connective tissue of the rats. In the control group, rats were operated on with no material being applied. Biocompatibilities of the bonding agents were evaluated according to tissue responses, histopathologic and biochemical TNF-alpha expressions, and levels of malondialdehyde, glutathione, superoxide dismutase and glutathione peroxidase activities 1 week and 1 month after initiation of treatment. Results: All neutrophil levels and edema formation between the iBond group and the other groups were statistically significant after 1 week. Fibroblast levels in the Clearfil SE Bond group were higher than all other groups. Vascularization levels statistically differed between the Clearfil SE Bond and iBond groups, and between the Adper Prompt L-Pop and control groups. Tissue TNF-alpha levels statistically differed in all groups other than the control group. At the end of 1 month, the neutrophil level in the iBond group was higher than that in the control group. The differences in fibroblast levels after 1 month were statistically significant between the Clearfil SE Bond and Clearfil Protect Bond groups, and between the control and iBond groups. Tissue TNF-alpha levels were higher in the iBond, Clearfil Protect Bond, and Adper Prompt L-Pop groups than in the Clearfil SE Bond and control groups. Conclusion: There were no statistical differences in levels of serum TNF-alpha and oxidative stress parameters in any groups during the course of the study. The four different adhesive systems exhibited different degrees of local toxicity to the subsurface of the skin of rats, but no systemic toxicity was detected.Öğe Sınıf V kavitelerde dezenfektanların mikrosızıntı üzerine etkisi: In vitro çalışma(2009) Dallı, Mehmet; İnce, Bayram; Şahbaz, Cafer; Bahşi, Emrullah; Çolak, Hakan; Zorba, Yahya Orçun; Ercan, ErtuğrulAmaç: Bu çalışmanın amacı klorheksidin içerikli üç farklı kavite dezenfektanın sınıf V kavitelerde mikrosızıntı üzerine etkisini in vitro şartlarda değerlendirmekti. Gereç ve Yöntem: Bu çalışmada 80 adet çürüksüz insan dişi kullanılmıştır. Sınıf V kaviteler, her dişin bukkal yüzeylerine mine-sement sınırından 1 mm aşağıda olacak şekilde standardize hazırlandı. Dişler her biri 20 disten oluşan rastgele 4 gruba ayrıldı. 1. Grup: kontrol grubu değerlendirildi herhangi bir dezenfektan uygulanmadı, 2.grupta %1 klorheksidin jel, 3.grupta % 2 klorheksidin glukonat solüsyonu ve 4. grupta % 0,2 klorheksidin glukonat solüsyonu uygulandı. Daha sonra kaviteler Xeno V(Dentsply DeTrey, Konstanz, Germany) adeziv ve Quxfill (Dentsply, Kontstanz, Germany) ile restore edildi. LED (Light Emitting Diode) ile polimerize edildi. Restorasyonların 1 mm. çevresi hariç dişlerin bütün yüzeyleri 2 tabaka tırnak cilası ile kaplandıktan sonra, 24 saat %2’lik metilen mavisi solüsyonunda bekletildi. Daha sonra dişler yıkanıp, bukkolingual yönde dikey olarak kesilerek x30 büyütmede stereomikroskop ile degerlendirildi. Sonuçlar Kruskal-Wallis testi ile istatistiksel olarak değerlendirildi. Bulgular: Kontrol grubu ile deney üç grup arasında mikrosızıntı skorları karşılaştırıldığında gruplar arasında istatistiksel anlamlı bir fark olmadıgı tespit edildi. (p0.05) Sonuç: Sınıf V kavitelerde klorheksidin içerikli değişik form ve oranlardaki kavite dezenfektanlarının self-etching adeziv ( Xeno V) öncesi uygulanmasının mikrosızıntı üzerine olumsuz bir etki göstermediği tespit edildi.