Bildiri ve Sunum Koleksiyonu
Bu koleksiyon için kalıcı URI
Güncel Gönderiler
Öğe Adaptation Study of the Newest Vital Sign on Adolescents With Type 1 Diabetes and Healthy Adolescents in Turkish(Lippincott Williams & Wilkins, 2022) Gümüş, Aylin Bayındır; Keser, Alev; Şıklar, Zeynep; Berberoglu, MerihThe current study aimed to establish validity and reliability of the Newest Vital Sign (NVS) in 255 Turkish adolescents aged 11 to 18 years with and without type 1 diabetes and evaluate their health literacy with age, gender, and health status. The t values of items in the NVS were found to be statistically significant and the calculated Cronbach's alpha coefficient value indicated that the reliability is at a medium level; 7.5%, 42%, and 56.5% of adolescents had respectively inadequate, limited, and adequate health literacy. There is a negative relationship between the health literacy of adolescents with diabetes and their HbA(1c) (P < .05). This study confirms that the NVS is a valid and reliable tool for Turkish adolescents.Öğe Status of the High Energy Booster of the lepton option of the future circular collider(Sissa Medialab Srl, 2022) Dalena, B.; Chance, A.; Antoniou, F.; Etisken, O.; Mashal, A.; Raubenheimer, T.; Zampetakis, M.In the context of the FCC IS European study, which investigates the feasibility of a 100 km circular e+e- collider for the future high-energy physics research, we present the design status of the High Energy Booster (HEB) ring. In order to perform precision measurements of the Z, W and H bosons, as well as of the top quark, unprecedented luminosities are required. To reach this goal and to fill the collider, it is mandatory to continuously top-up inject some beam with emittances comparable to those in the collider, so as to maintain an intensity difference between colliding electron and positron bunches below a few %. The main challenges of the HEB design are achieving the collider equilibrium emittances with a fast cycle, and determining the minimum booster injection energy allowing for stable operation. We present the status of the optics design of the HEB, taking into account the above challenges, and the impact of magnetic field imperfections on the dynamic aperture at injection. © Copyright owned by the author(s) under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (CC BY-NC-ND 4.0)Öğe Decreased UV-filtering ability of corneal epithelium may be the cause of stromal pathologies in keratoconus(Assoc Research Vision Ophthalmology Inc, 2017) Cagil, Nurullah; Yildiran, Fatma Azize Budak; Ugurlu, Nagihan; Tuncer, Sema; Turk, Mustafa; Caglayan, Mehtap; Sevli, Serhat…Öğe Selenium Ameliorates Cyclophosphamide - Induced Hepatotoxicity(Wiley-Blackwell, 2015) Ayhanci, Adnan; Acar, Ozge; Sahinturk, Varol; Gunes, Sibel; Sahin, Ilknur Kulcanay; Musmul, Ahmet; Uslu, Sema…










