Basit öğe kaydını göster

dc.contributor.authorSerel, Savas
dc.contributor.authorCavusoglu, Tarik
dc.contributor.authorUluc, Arsin
dc.contributor.authorAyva, Sebnem
dc.contributor.authorSaray, Aydin
dc.contributor.authorOzbek, Mustafa Riza
dc.date.accessioned2020-06-25T17:51:58Z
dc.date.available2020-06-25T17:51:58Z
dc.date.issued2011
dc.identifier.citationclosedAccessen_US
dc.identifier.issn1748-6815
dc.identifier.urihttps://doi.org/10.1016/j.bjps.2010.05.006
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5044
dc.descriptionWOS: 000287302800029en_US
dc.descriptionPubMed: 20542482en_US
dc.description.abstractCustom prefabrication of tissues allows the surgeon to build what is required for the reconstruction and has enabled the surgeon to reinforce new blood supply into selected blocks of tissue without vessel anastomosis. However, prefabricated flaps have several drawbacks and characteristics that differentiate them from conventional flaps. The objective of this study was to test the tolerance of prefabricated flaps to ischaemia/reperfusion injury in rats. In the first stage, the unilateral-inferior-epigastric pedicle was ligated and divided, and then a skin flap was fabricated by implantation of distally ligated femoral arteriovenous pedicle beneath the abdominal skin. The femoral vessels were implanted either in skeletonised or in muscle-cuffed fashion beneath the abdominal skin, a portion of which was raised as an island flap, based on these vessels. Prefabricated flaps (3 x 6 cm) were raised 6 weeks after, and were subjected to 10 h ischaemia and followed by 12 h reperfusion. Flap survival and histological changes at the pedicle-skin junction were evaluated at 7 days. Flap necrosis in the sham group was 0%, whereas the control group (conventional) had 47.27 +/- 13.50% necrosis. Flaps prefabricated with skeletonised femoral pedicle demonstrated an insignificant pattern with 63.74 +/- 10.62% necrosis when compared with prefabricated flaps with musclecuffed pedicle with the percentage of necrosis of 64.51 +/- 11.24. The area of necrosis was significantly increased when both the prefabricated flaps were compared with the control group or with the sham-prefabricated group (p < 0.05). Skin flaps prefabricated with either pedicle-alone or pedicles with muscle cuff are more susceptible to ischaemia and following reperfusion in comparison with the normal flaps. (C) 2010 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.en_US
dc.language.isoengen_US
dc.publisherElsevier Sci Ltden_US
dc.relation.isversionof10.1016/j.bjps.2010.05.006en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPrefabricationen_US
dc.subjectRaten_US
dc.subjectIschaemiaen_US
dc.subjectReperfusionen_US
dc.titleTolerance of prefabricated skin flaps to ischaemia and reperfusion: Experimental studyen_US
dc.typearticleen_US
dc.contributor.departmentKırıkkale Üniversitesien_US
dc.identifier.volume64en_US
dc.identifier.issue3en_US
dc.identifier.startpage394en_US
dc.identifier.endpage400en_US
dc.relation.journalJournal Of Plastic Reconstructive And Aesthetic Surgeryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster