Production cross-section calculations of medical P-32, Sn-117, Sm-153 and Re-186,Re-188 radionuclides used in bone pain palliation treatment
dc.contributor.author | Demir, B. | |
dc.contributor.author | Kaplan, A. | |
dc.contributor.author | Capali, V. | |
dc.contributor.author | Sarpun, I. . H. | |
dc.contributor.author | Aydin, A. | |
dc.contributor.author | Tel, E. | |
dc.date.accessioned | 2020-06-25T18:13:30Z | |
dc.date.available | 2020-06-25T18:13:30Z | |
dc.date.issued | 2015 | |
dc.department | Kırıkkale Üniversitesi | |
dc.description | SARPUN, Ismail Hakki/0000-0002-9788-699X | |
dc.description.abstract | In this study, production cross-section calculations of P-32, Sn-117, Sm-153 and Re-186,Re-188 radionuclides used in bone pain palliation treatment produced by Si-30(d,gamma)P-32, Sn-118(gamma,n)Sn-117, Sn-116(n,gamma)Sn-117, Nd-150(alpha,n)Sm-153, Sm-154(n,2n)Sm-153, Sm-152 (n,gamma)Sm-153, W-186(d,2n)Re-186, Re-187(gamma,n)Re-186, Re-185(n,gamma)Re-186 and Re-187(n,gamma)Re-188 reactions have been investigated in the different incident energy range of 0.003-34 MeV. Two-component exciton and generalised superfluid models of the TALYS 1.6 and exciton and generalised superfluid models of the EMPIRE 3.1 computer codes have been used to pre-equilibrium (PEQ) reaction calculations. The calculated production cross-section results have been compared with available experimental results existing in the experimental nuclear reaction database (EXFOR). Except the Sn-118(gamma,n)Sn-117, Nd-150 (alpha,n)Sm-153 and Re-185(n,gamma)Re-186 reactions, the two-component exciton model calculations of TALYS 1.6 code exhibit generally good agreement with the experimental measurements for all reactions used in this present study. | en_US |
dc.identifier.citation | closedAccess | en_US |
dc.identifier.doi | 10.3139/124.110477 | |
dc.identifier.endpage | 65 | en_US |
dc.identifier.issn | 0932-3902 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopus | 2-s2.0-84928946802 | |
dc.identifier.scopusquality | Q3 | |
dc.identifier.startpage | 58 | en_US |
dc.identifier.uri | https://doi.org/10.3139/124.110477 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/6210 | |
dc.identifier.volume | 80 | en_US |
dc.identifier.wos | WOS:000351750800008 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | Carl Hanser Verlag | en_US |
dc.relation.ispartof | Kerntechnik | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.title | Production cross-section calculations of medical P-32, Sn-117, Sm-153 and Re-186,Re-188 radionuclides used in bone pain palliation treatment | en_US |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
[ X ]
- İsim:
- Production cross-section calculations of medical P-32, Sn-117, Sm-153 and Re-186,Re-188 radionuclides used in bone pain palliation treatment.pdf
- Boyut:
- 1.78 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin/Full Text