Effect of Reinforcement Volume Ratio on Thermal Conductivity of SiO2 Reinforced Al Matrix Composite Produced by Vacuum Infiltration Method
[ X ]
Tarih
2010
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Asian Journal Of Chemistry
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this study, SiO2 powders with 105 mu m particle size were filled in quartz tubes freely to form 30, 40, 50% reinforcement volume ratios. Liquid A17075 alloy was vacuum infiltrated into the SiO2 compact under the same vacuum condition, the same time and at the same temperature in normal atmosphere for 3 min. After vacuuming, infiltration height and density of product composite have been determined. Microstructures of composites were investigated by SEM analysis. Two methods, finite element analysis method and experimental method. were used to determine thermal conductivity. The results of these methods were evaluated and compared. It has been found that the values of two different methods were quite near each other and thermal conductivity of composite increased with decreasing reinforcement volume ratio.
Açıklama
Anahtar Kelimeler
Composites, Infiltration, SiO2, Thermal conductivity
Kaynak
Asian Journal Of Chemistry
WoS Q Değeri
Q4
Scopus Q Değeri
Q4
Cilt
22
Sayı
1
Künye
closedAccess