Polyethylenimine-grafted and HSA-immobilized poly(GMA-MMA) affinity adsorbents for bilirubin removal
dc.contributor.author | Arıca, M.Yakup | |
dc.contributor.author | Yalçın, Emine | |
dc.contributor.author | Bayramoğlu, Gülay | |
dc.date.accessioned | 2020-06-25T15:13:35Z | |
dc.date.available | 2020-06-25T15:13:35Z | |
dc.date.issued | 2005 | |
dc.department | Kırıkkale Üniversitesi | |
dc.description.abstract | The epoxy-group-containing microspheres from cross-linked glycidyl methacrylate and methyl methacrylate, poly(GAM-MMA), were prepared by suspension polymerisation. The epoxy groups of the poly(GMA-MMA) microspheres were used for grafting with an anionic polymer polyethylenimine (PEI) to prepare non-specific affinity adsorbents (poly(GMA-MMA)-PEI) for bilirubin removal. The specificity of the poly(GMA-MMA)-PEI adsorbent to bilirubin was further increased by immobilization of human serum albumin (HSA) via adsorption onto PEI-grafted poly(GMA-MMA) adsorbent. Various amounts of HSA were immobilized on the poly(GMA-MMA)-PEI adsorbent by changing the medium pH and initial HSA concentration. The maximum HSA content was obtained at 68.3mg g-1 microspheres. The effects of pH, ionic strength, temperature and initial bilirubin concentration on the adsorption capacity of both adsorbents were investigated in a batch system. Separation of bilirubin from human serum was also investigated in a continuous-flow system. The bilirubin adsorption on the poly(GMA-MMA)-PEI and poly(GMA-MMA)-PEI-HSA was not well described by the Langmuir model, but obeyed the Freundlich isotherm model. The poly(GMA-MMA)-PEI affinity microspheres are stable when subjected to sanitization with sodium hydroxide after repeated adsorption-desorption cycles. © 2004 Society of Chemical Industry. | en_US |
dc.identifier.citation | closedAccess | en_US |
dc.identifier.doi | 10.1002/pi.1662 | |
dc.identifier.endpage | 160 | en_US |
dc.identifier.issn | 09598103 | |
dc.identifier.issue | 1 | en_US |
dc.identifier.scopus | 2-s2.0-11144320410 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 153 | en_US |
dc.identifier.uri | https://doi.org/10.1002/pi.1662 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/1856 | |
dc.identifier.volume | 54 | en_US |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.relation.ispartof | Polymer International | |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Bilirubin | en_US |
dc.subject | Grafting | en_US |
dc.subject | HSA | en_US |
dc.subject | Hydrogels | en_US |
dc.subject | Immobilization | en_US |
dc.subject | Microspheres | en_US |
dc.subject | PEI | en_US |
dc.title | Polyethylenimine-grafted and HSA-immobilized poly(GMA-MMA) affinity adsorbents for bilirubin removal | en_US |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
[ X ]
- İsim:
- Polyethylenimine-grafted and HSA-immobilized poly(GMA-MMA) affinity adsorbents for bilirubin removal.pdf
- Boyut:
- 148.98 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin/Full Text