Choosing Implant Type for Using with Allogeneic Bone Ring Graft: Guidance of Stress Analysis-Part I
dc.contributor.author | Ozgul, Ozkan | |
dc.contributor.author | Kocyigit, Ismail Doruk | |
dc.date.accessioned | 2020-06-25T18:29:44Z | |
dc.date.available | 2020-06-25T18:29:44Z | |
dc.date.issued | 2018 | |
dc.department | Kırıkkale Üniversitesi | |
dc.description.abstract | Objective: The aim of this study is to compare the stress distribution of three different implant macro design applied with allogeneic cancellous bone rings using three dimensional finite element analyses. Material and Methods: Finite element models of maxilla and mandible that augmented with allogeneic bone ring graft with implants were created. Vertical force of 100 N and oblique force of 100 N at 45 degrees angle were applied to three different (variable thread, cylindrical, standard thread) macro design implants. Results: Stress concentrations in the conjunction of neck of the implant and allogeneic bone ring were higher than other areas. The highest calculated values of Von Misses stresses were observed in standard thread implant with oblique loading in mandible model. In all models the highest stress values were greater for oblique loading compare to vertical loading. Discussion: Implant macro designs shows different distributions to implanted bone or graft. It should be considered when choosing an implant in the cases augmented with allogeneic cancellous bone ring. | en_US |
dc.description.sponsorship | Kirikkale University Scientific Research Project Department [2015/104] | en_US |
dc.description.sponsorship | This study supported by Kirikkale University Scientific Research Project Department. Project No: 2015/104. | en_US |
dc.identifier.citation | closedAccess | en_US |
dc.identifier.doi | 10.1166/jbt.2018.1737 | |
dc.identifier.endpage | 196 | en_US |
dc.identifier.issn | 2157-9083 | |
dc.identifier.issn | 2157-9091 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 190 | en_US |
dc.identifier.uri | https://doi.org/10.1166/jbt.2018.1737 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/7443 | |
dc.identifier.volume | 8 | en_US |
dc.identifier.wos | WOS:000429609000006 | |
dc.identifier.wosquality | Q4 | |
dc.indekslendigikaynak | Web of Science | |
dc.language.iso | en | |
dc.publisher | Amer Scientific Publishers | en_US |
dc.relation.ispartof | Journal Of Biomaterials And Tissue Engineering | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Allogeneic Bone Graft | en_US |
dc.subject | Implant Macro Design | en_US |
dc.subject | Finite Element Analysis | en_US |
dc.title | Choosing Implant Type for Using with Allogeneic Bone Ring Graft: Guidance of Stress Analysis-Part I | en_US |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
[ X ]
- Ä°sim:
- Choosing Implant Type for Using with Allogeneic Bone Ring Graft Guidance of Stress Analysis-Part I.pdf
- Boyut:
- 1 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin/Full Text