Matlab/Simulink Based Comparative Analysis of the Effect of Ion Concentration on Action Potantial by Using Hodgkin-Huxley and Morris-Lecar Neuron Models

dc.contributor.authorYalcinkaya, Fikret
dc.contributor.authorUnsal, Hamza
dc.date.accessioned2020-06-25T18:23:16Z
dc.date.available2020-06-25T18:23:16Z
dc.date.issued2017
dc.departmentKırıkkale Üniversitesi
dc.description21st National Biomedical Engineering Meeting (BIYOMUT) -- NOV 24-DEC 26, 2017 -- Istanbul, TURKEY
dc.description.abstractIn pharmacological experiments, the effect of ion concentrations on Action potential (AP) and its association with important neurological disorders such as stroke, epilepsy and depression has been investigated. In this paper, Hodgkin-Huxley (HH) and Morris-Lecar (ML) membrane models, which have contributed to the literature of theoretical neural science, have been studied. In the first step, these two models have been simulated individually in Simulink environment using Matlab software. In the second step, the ratio of the amount of extracellular ion to the amount of intracellular ion was expressed as Hd/Hi. Based on Na. and K. as ions, the effect of Hd/Hi ratio change on AP signal was investigated based on HH and ML as a model. In the HH model, it was searched that the Hd/Hi change due to sodium ions influenced the amplitude of AP and the depolarization phase. The change in Hd/Hi ratio due to potassium ion concentrations was found to affect the threshold and hyper-polarization phase of AP. In the ML membrane model, it was observed that the change in Hd/Hi ratio due to intracellular and extracellular Ca+2 and K- ion concentrations affected the formation time of AP, firing time, amplitude and formation phases. HH and ML models showed similarity in the same parameters.en_US
dc.identifier.citationclosedAccessen_US
dc.identifier.scopus2-s2.0-85056395749
dc.identifier.scopusqualityN/A
dc.identifier.urihttps://hdl.handle.net/20.500.12587/7056
dc.identifier.wosWOS:000447671500032
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isotr
dc.publisherIeeeen_US
dc.relation.ispartof2017 21St National Biomedical Engineering Meeting (Biyomut)
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAction Potentialen_US
dc.subjectHodgkin-Huxleyen_US
dc.subjectMorris-Lecaren_US
dc.subjectIon Concentrationen_US
dc.subjectMatlab / Simulinken_US
dc.subjectNeuron modelsen_US
dc.titleMatlab/Simulink Based Comparative Analysis of the Effect of Ion Concentration on Action Potantial by Using Hodgkin-Huxley and Morris-Lecar Neuron Modelsen_US
dc.typeConference Object

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Matlab Simulink Based Comparative Analysis of the Effect of Ion Concentration on Action Potantial by Using Hodgkin Huxley and Morris Lecar Neuron Models.pdf
Boyut:
382.7 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text