Effects of Short-Acting Anaesthetics on Haemodynamic Function as Determined by Doppler Ultrasonography in Rabbits

dc.authoridBOZTOK OZGERMEN, Basak/0000-0003-1264-3962
dc.authoridBoztok Ozgermen, Basak/0000-0001-7039-8956
dc.authoridSENEL, OYTUN OKAN/0000-0002-9008-9437
dc.contributor.authorKaya, Mahir
dc.contributor.authorPekcan, Zeynep
dc.contributor.authorSen, Yusuf
dc.contributor.authorBoztok, Basak
dc.contributor.authorSenel, Oytun Okan
dc.contributor.authorBumin, Ali
dc.date.accessioned2025-01-21T16:33:43Z
dc.date.available2025-01-21T16:33:43Z
dc.date.issued2011
dc.departmentKırıkkale Üniversitesi
dc.description.abstractThis study was carried out to determine the effects of short-acting anaesthetics on haemodynamic function determined by Doppler ultrasonography. Prior to anaesthesia, Doppler parameters [peak systolic blood flow velocity (psBFV), end-diastolic blood flow velocity (edBFV), minimum diastolic blood flow velocity (mdBFV) and resistive index (RI)] were obtained from the right common carotid artery (CCA), abdominal aorta (AA) and right kidney in New Zealand rabbits (n= 24). Animals were then divided into 3 groups to be anaesthetized with propofol (Group P), 2.5% thiopental sodium (Group T) and xylazine/ketamine HCl (Group XK). During anaesthesia the same Doppler measurements were made. Compared with baseline values, psBFV obtained from CCA increased in Group P (P < 0.02) and insignificantly changed in Groups T and XK. psBFV measured from AA in Groups T and XK decreased as compared with baseline values. In the right kidney, psBFV in Group P and edBFV in Group T increased, whereas RI value in Groups T and XK decreased. In conclusion, comparing baseline values, propofol anaesthesia did not significantly alter RI measured from CCA and kidney and blood flow velocities measured from AA. The data suggest that propofol anaesthesia in rabbits results in minimal changes in Doppler parameters.
dc.identifier.endpage719
dc.identifier.issn1300-6045
dc.identifier.issue5
dc.identifier.scopusqualityQ3
dc.identifier.startpage713
dc.identifier.trdizinid119855
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay119855
dc.identifier.urihttps://hdl.handle.net/20.500.12587/23844
dc.identifier.volume17
dc.identifier.wosWOS:000295359100005
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherKafkas Univ, Veteriner Fakultesi Dergisi
dc.relation.ispartofKafkas Universitesi Veteriner Fakultesi Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_20241229
dc.subjectShort-acting anaesthetic; Haemodynamic function; Doppler ultrasonography; Rabbit
dc.titleEffects of Short-Acting Anaesthetics on Haemodynamic Function as Determined by Doppler Ultrasonography in Rabbits