Clinical performance and biocompatibility of novel hyaluronan-based heparin-bonded extracorporeal circuits

dc.contributor.authorGünaydın, Serdar
dc.contributor.authorMccusker, Kevin
dc.contributor.authorVijay, Venkataramana
dc.date.accessioned2020-06-25T15:13:30Z
dc.date.available2020-06-25T15:13:30Z
dc.date.issued2005
dc.departmentKırıkkale Üniversitesi
dc.description.abstractWe tested documented in vitro and ex vivo advantages of novel hyaluronan based heparin bonded extracorporeal circuits in a prospective randomized study. During the period from June until September 2005, 40 patients undergoing reoperation for coronary artery bypass grafting were allocated into two equal groups (n = 20): Group 1 was treated with hyaluronan-based heparin-bonded circuits and group 2 was treated with uncoated control circuits. Complete blood count, fibrinogen, albumin, C3a, interleukin-2 levels, and thromboelastographic data were documented after induction of anesthesia (T1) and heparin administration before cardiopulmonary bypass (CPB) (T2), 15 minutes after initiation of CPB (T3), before cessation of CPB (T4), 15 minutes after reversal with protamine (T5), and the first postoperative day at 8:00 a.m. (T6). Hollow fibers were collected for consecutive biomaterial analysis by optical and scanning electron microscopy (SEM). Desorbed protein deposition on fibers was compared by spectrophotometry. Leukocyte counts were lower in T4-T6 in group 1 (p < .05). Platelet counts demonstrated significant differences at T4 and T5 in coated group (p < .05). Albumin and fibrinogen levels were better preserved in Group 1 at T4, T5 and T4, T6, consecutively (p < .05). C3a and IL-2 levels were lower at T3-T5 and T4-T5 in intervention group (p < .05). Postoperative hemorrhage was 412 ± 50 mL in group 1 and 684 ± 50 ml in group 2 (p < .05). Respiratory support time was shorter in group 1 versus control (p < .05). Platelet adhesion was significantly lower in intervention group. Amount of desorbed protein was 1.44 ± 0.01 mg/dL in group 1 and 1.94 ± 0.01 mg/dL in control (p < .05). SEM and spectrophotometry demonstrated better surface preservation in the hyaluronan coated group. Novel hyaluronan-based heparin-bonded circuits reduce platelet adhesion-aggregation and protein adsorption and provide better perioperative clinical parameters through platelet, albumin, and fibrinogen-sparing effects.en_US
dc.identifier.citationclosedAccessen_US
dc.identifier.endpage295en_US
dc.identifier.issn00221058
dc.identifier.issue3en_US
dc.identifier.pmid16350383
dc.identifier.scopus2-s2.0-31544462102
dc.identifier.scopusqualityQ2
dc.identifier.startpage290en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12587/1828
dc.identifier.volume37en_US
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.relation.ispartofJournal of Extra-Corporeal Technology
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCardiopulmonary bypass, coated materials, biocompatibilityen_US
dc.subjectMembrane oxygenators, extracorporeal circulationen_US
dc.titleClinical performance and biocompatibility of novel hyaluronan-based heparin-bonded extracorporeal circuitsen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Clinical performance and biocompatibility of novel hyaluronan-based heparin-bonded extracorporeal circuits.pdf
Boyut:
213.99 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin/Full text