Removal of cadmium(II) ions from human plasma by thionein modified pHEMA based membranes
dc.contributor.author | Denizli, F | |
dc.contributor.author | Arica, Y | |
dc.contributor.author | Denizli, A | |
dc.date.accessioned | 2020-06-25T17:34:42Z | |
dc.date.available | 2020-06-25T17:34:42Z | |
dc.date.issued | 2000 | |
dc.department | Kırıkkale Üniversitesi | |
dc.description.abstract | Microporous poly(2-hydroxyethylmethacrylate) [pHEMA] membranes carrying Cibacron Blue F3GA and/or thionein were prepared and used for cadmium(II) removal from human plasma. pHEMA membranes were produced by a photopolymerization of HEMA in the presence of azobisisobutyronitrile. The reactive dye-ligand Cibacron Blue F3GA was then covalently attached onto the pHEMA membranes. The maximum dye-loading was 1.07 mu mol/cm(2). Then, thionein was adsorbed onto the Cibacron Blue F3GA-carrying membranes. The maximum amount of thionein adsorbed was 0.92 mu mol/cm(2). The aqueous swelling properties and contact angle lair underwater) of the pHEMA membrane were not observed to change following derivatisation with Cibacron Blue F3GA. These hydrophilic membranes (contact angle value: 45.3 degrees) with a swelling ratio of 58% (w/w), and carrying Cibacron Blue F3GA and/or thionein were used in the Cd(II) removal studies. The maximum amounts of Cd(II) removed from human plasma by Cibacron Blue F3GA-attached and Cibacron Blue F3GA-attached/thionein adsorbed pHEMA membranes were of 1.72 mu mol used as pectively. Cd(II) ions could be repeatedly adsorbed and desorbed with both types of these novel metallo-peptide affinity pHEMA membranes without noticeable loss in their Cd(II) adsorption capacity. (C) 2000 Elsevier Science B.V. All rights reserved. | en_US |
dc.identifier.citation | closedAccess | en_US |
dc.identifier.doi | 10.1016/S1381-5148(99)00094-2 | |
dc.identifier.endpage | 217 | en_US |
dc.identifier.issn | 1381-5148 | |
dc.identifier.issue | 3 | en_US |
dc.identifier.scopus | 2-s2.0-0033721712 | |
dc.identifier.scopusquality | Q1 | |
dc.identifier.startpage | 207 | en_US |
dc.identifier.uri | https://doi.org/10.1016/S1381-5148(99)00094-2 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/2851 | |
dc.identifier.volume | 44 | en_US |
dc.identifier.wos | WOS:000088276300002 | |
dc.identifier.wosquality | Q1 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | Elsevier Science Bv | en_US |
dc.relation.ispartof | Reactive & Functional Polymers | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | cadmium removal | en_US |
dc.subject | plasma | en_US |
dc.subject | pHEMA | en_US |
dc.subject | thionein | en_US |
dc.title | Removal of cadmium(II) ions from human plasma by thionein modified pHEMA based membranes | en_US |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
[ X ]
- İsim:
- Removal of cadmium(II) ions from human plasma by thionein modified pHEMA based membranes.pdf
- Boyut:
- 528.79 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin/Full Text