Dental Implant Corrosion Products May Accumulate in the Human Body

[ X ]

Tarih

2024

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

W B Saunders Co-Elsevier Inc

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Background: Corrosion products resulting from the degradation of the dental implant surface due to biological fluids and infection may accumulate in the body and lead to clinical consequences. Purpose: The primary aim of this study is to measure the accumulation of dental implant corrosion products in the human body and the secondary aim is to estimate the association between corrosion products and fatigue. Study design, setting, sample: This study was designed as a prospective cross-sectional and was conducted with patients presenting at to the Department of Oral and Maxillofacial Surgery. The study included patients with Grade IV dental implants made of pure titanium (Ti) at the bone level and Grade V abutments composed of Ti, aluminum (Al), and vanadium (V). Individuals possessing different metallic implants and those prone to metal exposure were not included in the study. Blood and hair samples were procured from each participant and subsequently analyzed. Predictor variables: The predictor variable is implant exposure, and it was divided into 3 groups; Group I, patients with healthy dental implants; Group II, patients with peri-implantitis; Control Group, individuals without dental implants. Main outcome variables: The primary outcome variables are Al, Ti, V levels in blood and hair samples and the secondary outcome variable is the fatigue questionnaire score. Covariates: Age and gender, along with the dental implant number and duration of exposure within the study groups, are utilized as covariates. Analyses: Groups were compared using the Kruskal-Wallis and Mann-Whitney U-tests. Spearman's correlation coefficient determined relationships between groups, signifying significance with P values <.05. Results: The sample consisted of 30 patients aged 18 to 68, with 53% being female and 47% male. The differences among the 3 groups in the median values of blood Ti, V; hair Al, Ti, V; and fatigue questionnaire scores were not statistically significant (P > .05). However, the median blood Al value was statistically higher in Group II (P < .05). Conclusions and relevance: While the presence of healthy dental implants may not affect the accumulation of Al, Ti, and V within the body, patients with peri-implantitis exhibited elevated blood Al levels, possibly due to infection influencing the corrosion process.

Açıklama

Anahtar Kelimeler

Kaynak

Journal of Oral and Maxillofacial Surgery

WoS Q Değeri

Q2

Scopus Q Değeri

Q1

Cilt

82

Sayı

1

Künye