Biomechanical evaluation of malleable noncompression miniplates in mandibular angle fractures: an experimental study

dc.contributor.authorEsen, Alparslan
dc.contributor.authorDolanmaz, Doğan
dc.contributor.authorTuz, Hakan Hıfzı
dc.date.accessioned2020-06-25T18:06:33Z
dc.date.available2020-06-25T18:06:33Z
dc.date.issued2012
dc.departmentKırıkkale Üniversitesi
dc.descriptionEsen, Alparslan/0000-0001-7419-3210
dc.description.abstractThe purpose of this experimental study was to test the reliability of a single malleable titanium miniplate using Champy's method of fixing fractures of the mandibular angle. Eighteen sheep hemimandibles were used to evaluate 2 plating techniques. The groups were tested with either a single non-compression titanium miniplate or a single malleable titanium miniplate. A cantilever bending biomechanical test model was used for the samples. Each group was tested with vertical forces using a servohydraulic testing unit. The displacement values in each group at each 10 N stage up to 90 N were compared using 2-way analysis of variance (ANOVA). The displacement values for the 2 groups differed significantly (p < 0.01). The variance analyses showed that the biomechanical behaviour of a single non-compression miniplate was better than that of a single malleable miniplate. The non-compression miniplate fixed by screws had greater resistance to occlusal loads than the malleable plate fixed by screws, and the malleable plate alone was not sufficient to withstand the early postoperative bite force. (C) 2011 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.en_US
dc.identifier.citationclosedAccessen_US
dc.identifier.doi10.1016/j.bjoms.2011.10.013
dc.identifier.endpageE68en_US
dc.identifier.issn0266-4356
dc.identifier.issn1532-1940
dc.identifier.issue5en_US
dc.identifier.pmid22118919
dc.identifier.scopus2-s2.0-84862194860
dc.identifier.scopusqualityQ1
dc.identifier.startpageE65en_US
dc.identifier.urihttps://doi.org/10.1016/j.bjoms.2011.10.013
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5240
dc.identifier.volume50en_US
dc.identifier.wosWOS:000208858400001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherChurchill Livingstoneen_US
dc.relation.ispartofBritish Journal Of Oral & Maxillofacial Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMandibular angle fractureen_US
dc.subjectMalleable plateen_US
dc.subjectChampy methoden_US
dc.titleBiomechanical evaluation of malleable noncompression miniplates in mandibular angle fractures: an experimental studyen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Biomechanical evaluation of malleable noncompression miniplates in mandibular angle fractures an experimental study.pdf
Boyut:
487.88 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text