Strain and Shear Wave Elastography in Diagnosis of Retrobulbar Neuritis

dc.contributor.authorOgurel, Tevfik
dc.contributor.authorBurulday, Veysel
dc.date.accessioned2021-01-14T18:10:35Z
dc.date.available2021-01-14T18:10:35Z
dc.date.issued2020
dc.departmentKKÜ
dc.description.abstractBackground: In the early stages of retrobulbar neuritis (RN), the optic disc appears normal on ophthalmoscopy. Therefore, the diagnosis of RN is usually made clinically. However, imaging tools are needed for precise diagnosis of RN, and usually MRI is used. In this study, we investigated the diagnostic performance of strain elastography (SE) and shear wave elastography (SWE) in patients with RN. Elastography is a new sonographic technique and a noninvasive ultrasound method for evaluating the elastic properties of tissues based on static compression: the elastographic techniques of SE compress the tissues axially, and SWE uses waves that are generated by transducers and interact with the tissue. Methods: The study included 40 eyes of 20 patients with sudden visual loss, who were diagnosed with RN. The eyes of the patients were divided into 2 groups: the eye with a diagnosis of RN was the group of RN eyes, and the healthy second eye was the group of control eyes. Ophthalmologic examination, orbital and brain MRI, SE, and SWE were performed. SE color mapping was divided into 3 types: blue-hardest tissue (Type 1), blue/green-hard tissue (Type 2), and green-intermediate tissue (Type 3). All patients were treated with high-dose corticosteroids. The measurements of SE and SWE were made immediately after diagnosis and 1 month after treatment. Results: The mean age of 11 male and 9 female patients was 38.3 +/- 12.2 years. At the time of diagnosis, the mean shear wave values for the control eyes were 18.47 +/- 7.26 kPa (kilopascals), and the mean shear wave values for the RN eyes were 37.21 +/- 8.24 kPa. There was a statistically significant difference between the control and RN eyes at the time of diagnosis (P < 0.001). The mean shear wave value was 19.92 +/- 4.77 kPa in the RN eyes after treatment. There was a statistically significant difference in values at the time of diagnosis and after treatment (P < 0.001). Strain types found in the RN eyes before treatment were Type 1 in 60% of eyes, Type 2 in 25%, and Type 3 in 15%; at the end of the treatment, Type 2 was observed in 25% of eyes and Type 3 in 75%, while Type 1 was not observed. Conclusions: SE and SWE may be important alternative diagnostic tools in the diagnosis of RN.en_US
dc.identifier.citationBu makale açık erişimli değildir.en_US
dc.identifier.doi10.1097/WNO.0000000000000793
dc.identifier.endpage173en_US
dc.identifier.issn1070-8022
dc.identifier.issn1536-5166
dc.identifier.issue2en_US
dc.identifier.pmid31022061
dc.identifier.scopus2-s2.0-85084721334
dc.identifier.scopusqualityQ2
dc.identifier.startpage169en_US
dc.identifier.urihttps://doi.org/10.1097/WNO.0000000000000793
dc.identifier.urihttps://hdl.handle.net/20.500.12587/12686
dc.identifier.volume40en_US
dc.identifier.wosWOS:000539245000010
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherLIPPINCOTT WILLIAMS & WILKINSen_US
dc.relation.ispartofJOURNAL OF NEURO-OPHTHALMOLOGY
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleStrain and Shear Wave Elastography in Diagnosis of Retrobulbar Neuritisen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Strain_and_Shear_Wave_Elastography_in_Diagnosis_of.6.pdf
Boyut:
319.8 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam metin/Full text