Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis

dc.contributor.authorAkay, M
dc.contributor.authorAslan, N
dc.date.accessioned2020-06-25T17:34:34Z
dc.date.available2020-06-25T17:34:34Z
dc.date.issued1996
dc.departmentKırıkkale Üniversitesi
dc.description.abstractA comparative stress analysis of a polymeric composite hip joint replacement was performed. A prototype short carbon-fiber reinforced PEEK (CF/PEEK) prosthesis was manufactured by injection molding. Finite element (FE) analysis was conducted on intact femurs and femurs fitted with the CF/PEEK and the titanium prostheses under various loading conditions. FE models were validated by experimental strain gauge measurements by using synthetic femurs. There was a good agreement between the two methods except in the hoop strain of the femur in the calcar region because of the assumption of the isotropic material properties. The stem stresses were lower for the CF/PEEK prosthesis than for the titanium prosthesis. The maximum stress was in the spigot of the CF/PEEK prosthesis, but in the middle third of the stem of the titanium prosthesis. Stress generated in the cement was almost equal for both prostheses although more load was transferred, via cement, to the femur with the CF/PEEK prosthesis because the load transfer took place over a larger area. An out-of-plane component of the joint load causes higher prosthesis and cement stresses. (C) 1996 John Wiley & Sons, Inc.en_US
dc.identifier.citationclosedAccessen_US
dc.identifier.endpage182en_US
dc.identifier.issn0021-9304
dc.identifier.issue2en_US
dc.identifier.pmid8731205
dc.identifier.scopus2-s2.0-0030175796
dc.identifier.scopusqualityN/A
dc.identifier.startpage167en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12587/2770
dc.identifier.volume31en_US
dc.identifier.wosWOS:A1996UG00300003
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherJohn Wiley & Sons Incen_US
dc.relation.ispartofJournal Of Biomedical Materials Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleNumerical and experimental stress analysis of a polymeric composite hip joint prosthesisen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis.pdf
Boyut:
1.63 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text