Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study

dc.contributor.authorÇift, Harun
dc.contributor.authorCetik, Özgür
dc.contributor.authorKalaycıoğlu, Barış
dc.contributor.authorDirikoglu, M. H.
dc.contributor.authorÖzkan, Korhan
dc.contributor.authorEkşioğlu, Fatih
dc.date.accessioned2020-06-25T17:51:15Z
dc.date.available2020-06-25T17:51:15Z
dc.date.issued2010
dc.departmentKırıkkale Üniversitesi
dc.description.abstractIntroduction: The objective of this biomechanical study was to compare the respective efficiency of plate-screw fixation and screw fixation in an experimental model of a Schatzker type 4 fracture. Hypothesis: screw fixation and plate fixation have a similar load to failure. Materials and methods: This study compares the stability of Schatzker type 4 medial tibial plateau fractures fixed with either 36.5mm cancellous bone screw with a 16mm threaded segment or with six-holed buttress T-plate-screw system. A Schatzker type 4 fracture was modeled on an artificial bone model. In a first group of 10 fracture models, following the anatomical reduction, fractures were stabilized with screws with washers. In the second group, of 10 fracture models, fractures were stabilized with T-plate. After fixation ascending axial compression was applied on bone models (Instron machine). Results: Load bearing capacity was 1397.6 +/- 194.4 N in the Group 1 and 2153.2 +/- 204.4 N in the Group 2. The difference between the two groups was statistically significant (p < 0.001). Discussion: According to this result, experimental load bearing of bone models indicate that plate-screw fixation system has a significantly higher stabilization capacity than fixation with three screws alone. Our hypothesis was not confirmed. In order to maintain anatomical repositioning, plate-screw system is a more stable fixation method than the screw in medial tibial plateau fractures Schatzker 4 Level of evidence: 1. (C) 2010 Published by Elsevier Masson SAS.en_US
dc.identifier.citationCift, H., Cetik, O., Kalaycioglu, B., Dirikoglu, M. H., Ozkan, K., & Eksioglu, F. (2010). Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study. Orthopaedics & traumatology, surgery & research : OTSR, 96(3), 263–267. https://doi.org/10.1016/j.otsr.2009.11.016en_US
dc.identifier.doi10.1016/j.otsr.2009.11.016
dc.identifier.endpage267en_US
dc.identifier.issn1877-0568
dc.identifier.issue3en_US
dc.identifier.pmid20488145
dc.identifier.scopus2-s2.0-77952100022
dc.identifier.scopusqualityQ1
dc.identifier.startpage263en_US
dc.identifier.urihttps://doi.org/10.1016/j.otsr.2009.11.016
dc.identifier.urihttps://hdl.handle.net/20.500.12587/4756
dc.identifier.volume96en_US
dc.identifier.wosWOS:000277652300010
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Masson, Corporation Officeen_US
dc.relation.ispartofOrthopaedics & Traumatology-Surgery & Research
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectMedial tibial plateau fracturesen_US
dc.subjectBone modelen_US
dc.subjectFixationen_US
dc.titleBiomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model studyen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study.pdf
Boyut:
657.28 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text