Antibacterial Effects of Several Current Orthodontic Materials against Streptococcus mutans

dc.contributor.authorCatalbas, B.
dc.contributor.authorKamak, H.
dc.contributor.authorDemir, A.
dc.contributor.authorNur, M.
dc.contributor.authorHadimli, H. H.
dc.date.accessioned2020-06-25T17:52:27Z
dc.date.available2020-06-25T17:52:27Z
dc.date.issued2012
dc.departmentKırıkkale Üniversitesi
dc.descriptionKAMAK, HASAN/0000-0003-1910-3694
dc.description.abstractThe aim of this study was to examine the antibacterial effect of several current orthodontic materials against a certain oral bacterium. The antibacterial activities of six orthodontic composite resins (Transbond LR, Light Cure Retainer (LCR), Light Bond, System 1+, Kurasper E Transbond XT adhesive), two orthodontic bonding materials (Transbond XT primer and System 1+ activator) and two glass ionomer cements (GIC) [Multicure Glass Ionomer and Ketac Cem WC] were evaluated against Streptococcus mutans. The hard materials were put into the Teflon mould. The liquid materials were put on a paper disc. All materials were handled under aseptic conditions and placed on agar culture plates. All plates were incubated at 5% CO2 and 37 degrees C for 48 hours. The bacterial growth inhibition zones including the diameter of the sample were measured in millimetres. As a result of this study, the multicure GIC showed the highest antibacterial effectiveness, but no inhibition zones were noted for ketac cem GIC. The light bond adhesive of the Reliance orthodontic bonding system produced high antibacterial effect against S mutans, while the Reliance composite (LCR) did not show any antibacterial effect (p < 0.05). Both composite and primer of the transbond XT system demonstrated significant antibacterial effect against the test bacterium when compared to transbond LR (p < 0.05). Among the materials tested, kurasper F, Ormco system 1+ and system 1+ activator showed slight or no inhibitory effect against the test bacterium in this study. In patients who have relatively high salivary levels of Streptococci mutans before treatment, the multicure GIG, the Reliance light bond adhesive, and transbond XT system which had high level antibacterial properties could be applied.en_US
dc.identifier.citationclosedAccessen_US
dc.identifier.endpage825en_US
dc.identifier.issn0043-3144
dc.identifier.issue8en_US
dc.identifier.pmid23757904
dc.identifier.scopus2-s2.0-84884306375
dc.identifier.scopusqualityQ4
dc.identifier.startpage821en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5160
dc.identifier.volume61en_US
dc.identifier.wosWOS:000322424100010
dc.identifier.wosqualityQ4
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherUniv West Indies Faculty Medical Sciencesen_US
dc.relation.ispartofWest Indian Medical Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAntibacterial effecten_US
dc.subjectorthodontic materialsen_US
dc.subjectStreptococcus mutansen_US
dc.titleAntibacterial Effects of Several Current Orthodontic Materials against Streptococcus mutansen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Antibacterial Effects of Several Current Orthodontic Materials against Streptococcus mutans.pdf
Boyut:
119.95 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text