Symphyseal Bone Cylinders Tapping With the Dental Implant Into Insufficiency Bone Situated Esthetic Area at One-Stage Surgery: A Case Report and the Description of the New Technique

dc.contributor.authorTekin, Umut
dc.contributor.authorKocyigit, Doruk I.
dc.contributor.authorSahin, Volkan
dc.date.accessioned2020-06-25T17:51:37Z
dc.date.available2020-06-25T17:51:37Z
dc.date.issued2011
dc.departmentKırıkkale Üniversitesi
dc.description.abstractPeriodontal defects and trauma at the anterior maxillary region can cause a severe alveolar ridge deficiency resulting in an unesthetic view. Ideal implant positioning can be compromised by inadequate alveolar bone in terms of height and width. Reconstruction of osseous defects with autogenous bone allows ideal implant positioning and creates a more natural soft and hard tissue profile, which influences esthetic crown anatomy at the anterior maxillary region. In this case report, an alveolar ridge defect due to periodontally compromised tooth extraction was filled with autogenous bone cylinder and dental implant at one-stage surgery. In the presented case, a new technique was described which included bone reconstruction of the defects at the anterior maxillary region and simultaneous placement of the dental implant.en_US
dc.identifier.citationclosedAccessen_US
dc.identifier.doi10.1563/AAID-JOI-D-09-00096.1
dc.identifier.endpage594en_US
dc.identifier.issn0160-6972
dc.identifier.issue5en_US
dc.identifier.pmid20553126
dc.identifier.scopus2-s2.0-80054772266
dc.identifier.scopusqualityQ2
dc.identifier.startpage589en_US
dc.identifier.urihttps://doi.org/10.1563/AAID-JOI-D-09-00096.1
dc.identifier.urihttps://hdl.handle.net/20.500.12587/4934
dc.identifier.volume37en_US
dc.identifier.wosWOS:000296371000011
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherAllen Press Incen_US
dc.relation.ispartofJournal Of Oral Implantology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectalveolar bone defecten_US
dc.subjectsimultaneous implant placementen_US
dc.subjectcylinder bone graften_US
dc.titleSymphyseal Bone Cylinders Tapping With the Dental Implant Into Insufficiency Bone Situated Esthetic Area at One-Stage Surgery: A Case Report and the Description of the New Techniqueen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Symphyseal Bone Cylinders Tapping With the Dental Implant Into Insufficiency Bone Situated Esthetic Area at One-Stage Surgery A Case Report and the Description of the New Technique.pdf
Boyut:
2.71 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text