The effect of different adhesives and setting times on bond strength between Biodentine and composite
dc.contributor.author | Colak, Hakan | |
dc.contributor.author | Tokay, Ugur | |
dc.contributor.author | Uzgur, Recep | |
dc.contributor.author | Uzgur, Zeynep | |
dc.contributor.author | Ercan, Ertugrul | |
dc.contributor.author | Hamidi, Mehmet M. | |
dc.date.accessioned | 2020-06-25T18:16:40Z | |
dc.date.available | 2020-06-25T18:16:40Z | |
dc.date.issued | 2016 | |
dc.department | Kırıkkale Üniversitesi | |
dc.description | Colak, Hakan/0000-0001-8262-0913; Hamidi, Mehmet Mustafa/0000-0003-3461-7925; ERCAN, Ertugrul/0000-0002-4753-6553 | |
dc.description.abstract | Background: The aim of this study was to evaluate the effects of 3 different adhesives with different functional monomers, on the shear bond strength (SBS) of Biodentine (R). Methods: Acrylic blocks (n = 90) were prepared and a 2-mm height x 4-mm diameter hole was opened in each block. Every hole was completely restored with Biodentine (R). Before preparation of composite restorations over the Biodentine (R) (2-mm height x 2-mm diameter), 3 different adhesives (Etch-37 (37%) w/BAC by Bisco & Prime Bond N&T, Clearfil S-3 Bond and Adper Prompt L-Pop) were applied. SBS was evaluated using a universal testing machine, and failure mode for each sample was recorded. The results were statistically analyzed using 2-way ANOVA and post hoc Tukey test. Results: When the megapascal values of all groups were compared, although there was no statistically significant difference in the different setting times (p>0.05), statistically significant differences were observed among all adhesive groups (p<0.05). Moreover, the highest SBS values were observed in the Clearfil S-3 Bond group. Conclusions: Clinical performance of Biodentine (R) may be affected by adhesive procedures and its setting time. | en_US |
dc.identifier.citation | Çolak H, Tokay U, Uzgur R, Uzgur Z, Ercan E, Hamidi MM. The Effect of Different Adhesives and Setting Times on Bond Strength between Biodentine and Composite. Journal of Applied Biomaterials & Functional Materials. 2016;14(2):217-222. | en_US |
dc.identifier.doi | 10.5301/jabfm.5000266 | |
dc.identifier.endpage | E222 | en_US |
dc.identifier.issn | 2280-8000 | |
dc.identifier.issue | 2 | en_US |
dc.identifier.pmid | 27149941 | |
dc.identifier.scopus | 2-s2.0-84969902819 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | E217 | en_US |
dc.identifier.uri | https://doi.org/10.5301/jabfm.5000266 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/6590 | |
dc.identifier.volume | 14 | en_US |
dc.identifier.wos | WOS:000388385600012 | |
dc.identifier.wosquality | Q3 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.language.iso | en | |
dc.publisher | Wichtig Publishing | en_US |
dc.relation.ispartof | Journal Of Applied Biomaterials & Functional Materials | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Biodentine (R) | en_US |
dc.subject | Self-etch adhesives | en_US |
dc.subject | SEM | en_US |
dc.subject | Shear bond strength test | en_US |
dc.subject | Total-etch | en_US |
dc.title | The effect of different adhesives and setting times on bond strength between Biodentine and composite | en_US |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
Yükleniyor...
- İsim:
- The effect of different adhesives and setting times on bond strength between Biodentine and composite.pdf
- Boyut:
- 1 MB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin/Full Text