Effects of different fissure sealant applications on laser fluorescence measurements

dc.contributor.authorSonmez, Isil Saroglu
dc.contributor.authorOba, Aylin Akbay
dc.contributor.authorErkmen, Merve
dc.contributor.authorEkici, Seda
dc.date.accessioned2020-06-25T17:52:16Z
dc.date.available2020-06-25T17:52:16Z
dc.date.issued2011
dc.departmentKırıkkale Üniversitesi
dc.descriptionsonmez, isil/0000-0002-3530-0244
dc.description.abstractObjective. The aim of this in vitro study was to evaluate the effects of using only phosphoric acid or a self-etch bonding agent under clear and opaque fissure sealants on laser fluorescence (LF) readings and the reproducibility of the laser device. Methods. Eighty extracted permanent molars, ranged from sound to carious, were randomly divided into four groups: phosphoric acid + opaque sealant (group I), Clearfil S3 Bond (Kuraray, Kurashiki, Japan) + opaque sealant (group II), phosphoric acid + clear sealant (group III), and Clearfil S3 Bond + clear sealant (group IV). The teeth were measured using an LFpen device, before and after sealing. Data were analysed using the Spearman's correlation, Wilcoxon signed rank, and Mann-Whitney U-test. Results. Except group IV, there was a statistically significant decrease in fluorescence after the application of sealants (P < 0.05). The decrease of LFpen readings in the opaque sealant groups was more significant than the clear sealant groups (P < 0.05). But for both sealants, the difference between phosphoric acid and Clearfil S3 Bond groups was nonsignificant (P > 0.05). Conclusions. There was a statistically significant decrease in fluorescence for both clear and opaque sealant groups. However, clear sealant with Clearfil S3 Bond does not influence the LFpen readings.en_US
dc.identifier.citationclosedAccessen_US
dc.identifier.doi10.1111/j.1365-263X.2010.01076.x
dc.identifier.endpage34en_US
dc.identifier.issn0960-7439
dc.identifier.issn1365-263X
dc.identifier.issue1en_US
dc.identifier.pmid20659181
dc.identifier.scopus2-s2.0-78650158711
dc.identifier.scopusqualityQ1
dc.identifier.startpage29en_US
dc.identifier.urihttps://doi.org/10.1111/j.1365-263X.2010.01076.x
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5120
dc.identifier.volume21en_US
dc.identifier.wosWOS:000285063100004
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherWileyen_US
dc.relation.ispartofInternational Journal Of Paediatric Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleEffects of different fissure sealant applications on laser fluorescence measurementsen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
Effects of different fissure sealant applications on laser fluorescence measurements.pdf
Boyut:
75.39 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text