Implantation metastasis caused by fine needle aspiration biopsy following curative resection of stage IB non-small cell lung cancer

dc.contributor.authorKara, M
dc.contributor.authorAlver, G
dc.contributor.authorSak, SD
dc.contributor.authorKavukcu, S
dc.date.accessioned2020-06-25T17:34:47Z
dc.date.available2020-06-25T17:34:47Z
dc.date.issued2001
dc.departmentKırıkkale Üniversitesi
dc.descriptionSak, Serpil/0000-0003-3666-3095; kavukcu, salih/0000-0002-9959-881X
dc.description.abstractFine needle aspiration is a useful procedure in the diagnosis of lung cancer. however controversy still remains as to whether it should be employed particularly in patients with operable lung cancer. We report herein a case of metastatic tumor at the site of transthoracic needle biopsy following a curative resection in a patient with stage IB bronchogenic carcinoma. The patient was managed with aggressive chest wall resection and subsequent musculocutaneus flap transposition. however he died I I months after the initial operation. The tumor implantation risk and the related complications should be considered in patients with operable bronchogenic carcinoma undergoing a tranthoracic needle aspiration biopsy. (C) 2001 Elsevier Science B.V. All rights reserved.en_US
dc.identifier.citationKara, M., Alver, G., Sak, S. D., & Kavukçu, S. (2001). Implantation metastasis caused by fine needle aspiration biopsy following curative resection of stage IB non-small cell lung cancer. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery, 20(4), 868–870.en_US
dc.identifier.doi10.1016/S1010-7940(01)00866-1
dc.identifier.endpage870en_US
dc.identifier.issn1010-7940
dc.identifier.issn1873-734X
dc.identifier.issue4en_US
dc.identifier.pmid11574245
dc.identifier.scopus2-s2.0-0035489074
dc.identifier.scopusqualityQ1
dc.identifier.startpage868en_US
dc.identifier.urihttps://doi.org/10.1016/S1010-7940(01)00866-1
dc.identifier.urihttps://hdl.handle.net/20.500.12587/2894
dc.identifier.volume20en_US
dc.identifier.wosWOS:000171527900047
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherOxford Univ Press Incen_US
dc.relation.ispartofEuropean Journal Of Cardio-Thoracic Surgery
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjecttransthoracic needle biopsyen_US
dc.subjectlung canceren_US
dc.subjectrecurrenceen_US
dc.titleImplantation metastasis caused by fine needle aspiration biopsy following curative resection of stage IB non-small cell lung canceren_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Implantation metastasis caused by fine needle aspiration biopsy following curative resection of stage IB non-small cell lung cancer.pdf
Boyut:
1.64 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text