Pentylenetetrazol-induced seizures are not altered by pre- or post-drug exposure to a 50 Hz magnetic field
dc.contributor.author | Canseven, Ayşe G. | |
dc.contributor.author | Keskil, Zuhal Aktuna | |
dc.contributor.author | Keskil, Semih | |
dc.contributor.author | Seyhan, Nesrin | |
dc.date.accessioned | 2020-06-25T17:43:52Z | |
dc.date.available | 2020-06-25T17:43:52Z | |
dc.date.issued | 2007 | |
dc.description.abstract | Purpose: To investigate whether pre- and post-drug magnetic field (MF) exposure of 50 Hz, 0.2 mT has any significant effect on pentylenetetrazol (PTZ)-induced seizures in mice. Material and methods: MF was generated by a pair of Helmholtz coils. Seizures were induced by PTZ injection intraperitoneally (i.p.) at a dose of 60 mg/kg. A total of 48 locally bred adult female mice 25 - 35 g in weight were used. Latency to seizure, total seizure duration, and mortality were recorded for each mouse. Results: Neither pre- nor post-drug exposure to a 50 Hz, 0.2 mT MF was found to have any effect on PTZ-induced epileptic seizures or mortality rates in mice. Conclusion: The present study failed to provide any support for a therapeutic potential of a 50 Hz, 0.2 mT MF for epilepsy. | en_US |
dc.identifier.citation | closedAccess | en_US |
dc.identifier.doi | 10.1080/09553000701206676 | |
dc.identifier.endpage | 235 | en_US |
dc.identifier.issn | 0955-3002 | |
dc.identifier.issn | 1362-3095 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.pmid | 17575950 | |
dc.identifier.scopus | 2-s2.0-33947119188 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 231 | en_US |
dc.identifier.uri | https://doi.org10.1080/09553000701206676 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12587/3931 | |
dc.identifier.volume | 83 | en_US |
dc.identifier.wos | WOS:000246068200003 | |
dc.identifier.wosquality | Q1 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.indekslendigikaynak | PubMed | |
dc.language.iso | en | |
dc.publisher | Taylor & Francis Ltd | en_US |
dc.relation.ispartof | International Journal Of Radiation Biology | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | 50 Hz | en_US |
dc.subject | extremely low frequency (ELF) | en_US |
dc.subject | magnetic field (MF) | en_US |
dc.subject | epilepsy | en_US |
dc.subject | pentylenetetrazol (PTZ) | en_US |
dc.title | Pentylenetetrazol-induced seizures are not altered by pre- or post-drug exposure to a 50 Hz magnetic field | en_US |
dc.type | Article |
Dosyalar
Orijinal paket
1 - 1 / 1
[ X ]
- İsim:
- Pentylenetetrazol-induced seizures are not altered by pre- or post-drug exposure to a 50 Hz magnetic fie.pdf
- Boyut:
- 479.15 KB
- Biçim:
- Adobe Portable Document Format
- Açıklama:
- Tam Metin/Full Text