Development of poly(3-aminophenylboronic acid) modified graphite rod electrode suitable for fluoride determination
Yükleniyor...
Tarih
2014
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Elsevier Science Bv
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Poly(3-aminophenylboronic acid), (PAPBA) film was formed on the graphite rod surface by potential cycling. The PAPBA-modified graphite rod (PAPBA/GR) electrode prepared in this way was used for potentiometric fluoride determination. The linear calibration range was from 5 x 10(-4) to 5 x 10(-2) M with the slope of the linear part of the calibration curve of 42.5 mV/log C. No interference effect of the most common ions such as sodium, potassium, chloride, nitrate, iodide, calcium, zinc, aluminum, sulfate and sorbitol was observed during electrochemical determination of fluoride. On the other hand, the PAPBA/GR electrode showed not only good sensitivity and selectivity, but also relatively rapid response to changes of analyte concentrations in the range of 20 s. The sensor was successfully applied for fluoride determination in real sample - toothpaste. (C) 2014 Elsevier B.V. All rights reserved.
Açıklama
Tamer, Ugur/0000-0001-9989-6123; Ramanavicius, Arunas/0000-0002-0885-3556
Anahtar Kelimeler
Poly(3-aminophenylboronic acid), Fluoride, Potentiometry, Conducting polymer, Ion-selective electrode
Kaynak
Talanta
WoS Q Değeri
Q1
Scopus Q Değeri
Q1
Cilt
126
Sayı
Künye
closedAccess